BACKGROUND An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS). The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. FINDINGS THE EXPERIMENTAL STUDY WAS OPERATED WITH TWO MODES: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. CONCLUSIONS On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively.
منابع مشابه
The Effect of the Variation of Volume Flow Rate on the Thermal Parameters of a Solar Air Collector with a Single Pass of Air: Case Study for Laghouat, Algeria
The effect of the volume flow rate of the heat transfer fluid (air) on the thermal parameters of the solar air collector with a single air pass without using fins under the absorbing plate have been investigated experimentally and theoretically. We use a new design of solar air collector which aims to optimize these parameters in the region cited above. Our solar air collector was realized at t...
متن کاملDynamic Response Analysis of the Planar and Tubular Solid Oxide Fuel Cells to the Inlet Air Mass Flow Rate Variation
The purpose of present study is to investigate the dynamic response of two conventional types of solid oxide fuel cells to the inlet air mass flow rate variation. A dynamic compartmental model based on CFD principles is developed for two typical planar and tubular SOFC designs. The model accounts for transport processes (heat and mass transfer), diffusion processes, electrochemical processes, a...
متن کاملModeling and thermal parametric analysis of U-pipe evacuated tube solar collector for four different climates in Iran
In this study, thermal performance of the collector with analytic and quasi-dynamic method is evaluated based on energy balance equations for each part of the U-pipe evacuated tube solar collector. Using this approach, effect of different parameters such as tube size, overall heat loss coefficient, absorber tube absorptivity, mass flow rate and air layer thermal resistance on thermal performanc...
متن کاملExperimental Investigation of the Efficiency of a Semi-Spherical Solar piping Collector
Solar water heaters are good tools for saving fuel. The main component of these water heaters is collectors, which are responsible for absorbing solar energy and transferring it to the working fluid with the least heat dissipation. The present study is an experimental study of the performance of the solar semispherical collector with 1 m2 of absorber area at different volumetric flow...
متن کاملAn experimental investigation of performance of a 3-D solar conical collector at different flow rates
The shape of a solar collector is an important factor in solar-to-thermal energy conversion. Conical shape is one of the stationary and symmetric shapes that can be employed as a solar water heater. Flow rate of working fluid on the solar collector has an important effect on the efficiency of the collector. The present study is an experimentally investigated of the performance of the solar coni...