Every doctor should be able to make a probable diagnosis of congestive heart failure by clinical examination. The most revealing clinical sign is an elevated jugular venous pressure. The measurement of this pressure was introduced by Lewis in 1930 and refined and standardised by Borst and Molhuysen in 1952. Still, this method has fallen into disuse and is thought to be not very sensitive for diagnosing congestive heart failure. A study of the methods described in the literature reveals that variations in technique are responsible for great differences in normal values. It is argued that smaller elevations of jugular venous pressure can only be measured reliably by adhering strictly to the conditions put forward by Borst and Molhuysen. In this way the sensitivity will improve considerably. A plea is made for an intensive training in this method for doctors and medical students.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Physical examination of venous pressure: a critical review.

OBJECTIVE To explain why investigations of the measurement of central venous pressure (CVP) usually reveal a discrepancy between the clinician's estimate of CVP from physical diagnosis and supine measurement with a catheter. Data from MEDLINE search, personal files, and bibliographies of textbooks on physical diagnosis and cardiology were used. RESULTS The most important reasons for this disa...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

Central Venous Pressure Monitoring; Introduction of a New Device

Hemodynamic monitoring is needed in up to 58% of patients presented to the emergency department (1). Although central venous pressure (CVP) monitoring is generally useful to assess general volume status, its reliability as a guide to resuscitation in critically ill patients is a subject of debate (2, 3). Generally, there are several methods of CVP measurement, which can be categorized as invasi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Netherlands journal of medicine

دوره 61 7  شماره 

صفحات  -

تاریخ انتشار 2003