Geometrically weighted semiconductor Frisch grid radiation spectrometers

نویسندگان

  • D. S. McGregor
  • M. Blakely
چکیده

A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correction, and it requires only one signal output to any commercially available charge sensitive preamplifier. The device operates very well with conventional NIM electronic systems. Presently, room temperature (23°C) energy resolutions of 2.68% FWHM at 662keV and 2.45% FWHM at 1.332MeV have been measured with a 1 cm3 prism shaped CdZnTe device. ( 1999 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of virtual Frisch-grid CdZnTe detector designs for imaging and spectroscopy of gamma rays

In the past, various virtual Frisch-grid designs have been proposed for cadmium zinc telluride (CZT) and other compound semiconductor detectors. These include three-terminal, semi-spherical, CAPture, Frisch-ring, capacitive Frisch-grid and pixel devices (along with their modifications). Among them, the Frisch-grid design employing a noncontacting ring extended over the entire side surfaces of p...

متن کامل

A high pressure xenon gamma-ray spectrometer using a coplanar anode configuration

A new design of a high pressure xenon ionization chamber has been fabricated in an attempt to eliminate the problems associated with acoustical vibrations of the Frisch grid. The function of the traditional Frisch grid has been accomplished by employing a coplanar anode system capable of single polarity charge sensing. Two different detector designs have been fabricated using both cylindrical a...

متن کامل

New Results from Performance Studies of Frisch-Grid CdZnTe Detectors

New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...

متن کامل

Angular response of a W-collimated room-temperature-operated CdZnTe Frisch collar spectrometer

The spatial resolution of a collimated CdZnTe Frisch collar detector was experimentally investigated for two different tungsten collimator designs using a Au gamma-ray source at 412 keV. A two-dimensional model for the detector–collimator–source geometry was developed and applied with some simplifying assumptions. The CdZnTe detector was fabricated from a single crystal using a copper shim as t...

متن کامل

Charge Collection Characteristics of Frisch Collar CdZnTe Gamma Ray Spectrometers

A collimated Au source was used to determine the charge collection efficiency (CCE) at several locations along the length of a 3.4 x 3.4 x 5.5 mm CdZnTe bar detector both in planar configuration and with Frisch collars of varying length. For each configuration, a 0.50 mm long region spanning the width of the device was irradiated with 411 keV gamma rays produced by a neutron activated gold foil...