Corn Density Measurement by Near-infrared Transmittance

نویسندگان

  • Juraj Siska
  • J. Siska
چکیده

A corn density calibration was developed for a near-infrared transmittance instrument (Infratec 1225). The calibration sample set included 96 corn samples grown in various locations of the United States. Samples were selected by principal component analysis (PCA) from a larger set of 410 samples, representing the 1986 through 1992 crop years. Samples for instrument and temperature stabilization were included in the calibration. The partial least squares calibration was then validated with 35 randomly selected samples not in the calibration sample set. With 14 PCA factors, the standard error of calibration was 0.0173 g/cm3, and the standard error of prediction was 0.0164 g/cm3. Fourteen factors were required because the first 12 reflected the physical correlations of density to protein and density to starch.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Seed Size and Density on Near-infrared Transmittance Analysis of Corn and Soybeans

Soybean physical and chemical properties changed by size (from 4.8 to 8.8 mm diameter), but soybean size and seed density did not affect the protein and oil determination accuracy of three near-infrared transmission analyzers. Corn samples were also separated by size and kernel density. Changes in corn kernel density and size introduced small errors in near-infrared transmission protein, oil, a...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Using Aerial Hyperspectral Remote Sensing Imagery to Estimate Corn Plant Stand Density

Since corn plant stand density is important for optimizing crop yield, several researchers have recently developed ground‐based systems for automatic measurement of this crop growth parameter. Our objective was to use data from such a system to assess the potential for estimation of corn plant stand density using remote sensing images. Aerial hyperspectral remote sensing imagery was collected o...

متن کامل

Estimating Leaf Water Status from Vis-nir Reflectance and Transmittance

Remotely sensing the water status of plant canopies remains a long term goal of remote sensing research. Established approaches involve measurements in the thermal infrared and the 900-2000nm reflective infrared. Less popular UVvisible-NIR techniques presumably deserve research attention, because photochemical changes linked to plant water status manifest spectral light scattering and absorptio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017