High Dynamic Range Microscopy for Color Selective Virtual De-Staining of Immunocytological Specimens

نویسندگان

  • David Friedrich
  • André A. Bell
  • Kraisorn Chaisaowong
  • Till Braunschweig
  • Ruth Knüchel-Clarke
  • Til Aach
چکیده

Immunocytochemical markers are increasingly applied for diagnosis of diseases. Usually two or more marker stains are applied at once, together with a counterstain for a reliable microscopic investigation of cell specimens. As a preprocessing step for the detection of marker-positive cells, other stains should be removed by image processing techniques. This virtual destaining can be achieved by color separation algorithms, thus removing the undesired stain and reconstructing an image containing only the desired marker component. Known algorithms for color separation however show significant color artifacts, which are caused by inevitable non-linearities during image acquisition. In this paper we develop high dynamic range (HDR) microscopy color separation, which removes non-linearities, dynamic range limitations, as well as quantization effects and enables accurate color separation and virtual destaining. Color accuracy in the virtual destained images is provided by the ∆E00 measure. Our simulations demonstrate that the perceivable color error is reduced from 86% to 0.65%. Finally, we provide results for HDR-based virtual destaining on cell samples from cytopathological routine which confirm the performance of our approach.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه ای شدت رنگ پذیری مارکر p63 برش های مجدد (Recut) با برش های رنگ زدایی شده (Destained) نمونه بیماران مبتلا به سرطان ریه

Background and purpose: Several studies have been carried out on re-cut and de-stained sections regarding prostate biopsies and cytologic specimens of squamous cell carcinoma. However, few studies on lung biopsy are done. Due to small size of lung biopsies and for the prevention of lung rebiopsy, in this study P63 staining intensity between re-cut and de-stained slides of patients, specimens ...

متن کامل

Plastination and Staining of Brain Slices Using Two Different Dehydration Methods

Introduction: Unstained formalin-fixed whole brain specimens and brain slices do not give satisfactory results for teaching neuroanatomy. In addition, difficulties in obtaining human brains for dissection have increased the demand for more durable brain specimens that have been obtained by the plastination technique. In the present study brain specimens were sliced, fixed and stained using...

متن کامل

Color Stability of a Microhybrid Resin Composite Polymerized with LED and QTH Light Curing Units

Introduction: Discoloration of resin composites is a common reason for replacement of these restorations. The aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite.  Materials and Methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek Z250 resin composite. Specimens wer...

متن کامل

Effect of staining solutions and repolishing on color stability of direct composites

OBJECTIVES The purpose of this study was to assess the color change of three types of composite resins exposed to coffee and cola drink, and the effect of repolishing on the color stability of these composites after staining. MATERIALS AND METHODS Fifteen specimens (15 mm diameter and 2 mm thick) were fabricated from microhybrid (Esthet-X; Dentsply and Filtek Z-250; 3M ESPE) and high-density ...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011