Radiation Exposure to the Surgeon and Patient During a Fluoroscopic Procedure: How High Is the Exposure Dose? A Cadaveric Study.

نویسندگان

  • Kazuta Yamashita
  • Kosaku Higashino
  • Keizo Wada
  • Masatoshi Morimoto
  • Mitsunobu Abe
  • Yoichiro Takata
  • Toshinori Sakai
  • Yoshihiro Fukui
  • Koichi Sairyo
چکیده

STUDY DESIGN Using fresh cadavers, real-time dosimeters were used to estimate the radiation exposure dose from C-arm fluoroscopy to surgeons, medical staff, and patients during various procedures. OBJECTIVE The aim of this study was to evaluate the radiation exposure dose from C-arm fluoroscopy, which is used to generate real-time images of the human body, under a variety of conditions and in different areas. SUMMARY OF BACKGROUND DATA Awareness of the harmful effects of long-term low-dose radiation is rising. There are no all-inclusive reports evaluating the radiation exposure dose to medical staff associated with fluoroscopic procedures that can accurately simulate the real clinical situation. METHODS Seven fresh cadavers were irradiated for 1, 3, and 5 minutes with C-arm fluoroscopy. The x-ray source was positioned under the table, over the table, and laterally. Radiation exposure doses were measured at different simulated areas such as the center area, and the surgeon's hand or thyroid gland. RESULTS There were significant differences in the radiation exposure dose under different conditions and for different irradiated areas. The risk of direct and scatter radiation exposure was the greatest with the lateral position, which increased by more than 200 times and more than 30 times, respectively, compared with that from a position under the table. Direct radiation was attenuated to less than one-hundredth after passing through the body of the cadaver. All radiation exposure doses were positively correlated with total exposure time. CONCLUSION Our study revealed the direct and scatter radiation exposure dose from C-arm fluoroscopy to different areas under a variety of conditions when fluoroscopy is used to generate real-time images of the human body. Our results serve as a guide for medical staff to understand the risk of radiation exposure during each fluoroscopic procedure. Medical staff, especially surgeons, should consider how to protect themselves and reduce radiation exposure by using appropriate shielding. LEVEL OF EVIDENCE 4.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure during percutaneous nephrolithotomy; Is there a risk of the patient and the operating team?

Background: The aim of this study was to calculate the radiation amount exposed during percutaneous nephrolithototomy (PCNL) and to make the urologists and other staff sensitive about the radiation risk they were exposed to. Materials and Methods: We measured the radiation exposure during 114 cases of PCNL performed. Thermoluminescent dosimeters (TLD) were placed between the operation table and...

متن کامل

Perioperative radiation exposure in a pregnant woman

The perioperative imaging of a pregnant woman presents a unique challenge to orthopaedics surgeon as concern about the radiation risk to the embryo or fetus. This article highlights effect of radiation exposure on foetus.I would like to discuss about the amount of radiation exposure in a pregnant woman during fluoroscopic guided closed femoral Interlock nailing as radiation has significant...

متن کامل

Estimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient

Background:  The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 41 15  شماره 

صفحات  -

تاریخ انتشار 2016