1346 Title: Does the lens of the eye possess a coordinated volume regulatory system?

نویسندگان

  • T.J.C. Jacob
  • Jin Jun Zhang
چکیده

pumoSe The purpose of this study was to investigate the role of Clchannel) in lens volume regulation and its involvement in cataractogenesis. There is considerable evidence that lens swelling precedes opacification. The primary role of the lens is to focus light onto the retina and a prerequisite for achieving this is to maintain lens transparency Questions therefore to be addressed arej how can the lens maintain its special ptrysiological strxture and do the lens fibre cells need a regulatory system to keep their volume constant? Ma (1) Vesicles were formed thorn posterior bovine lens fibre cells and used for “cell-attached” patch clamping (2) The viable fibre cells containing nuclei were plated onto a coverslip coated with cooling agar. (3) Digital images of lenses were taken at intervals with a CCD camera and the anteriorposterior (A-P) and equatorial diameters were measured R& When the lens tibre cell vesicle:; were exposed to 30% hypotonic solution single Clchannel activity (g=lSpS) increased in vesicle-attached patches Additionally, hypotonic solution induced an outwardly rectifying current in whole-cell recordings from posterior fibre cells, which reversed at the chloride equilibrium potential and was reversibly inhibited by chloride channel blockers (e.g NPPB and tamoxifen). When whole bovine lenses werb exposed to 50% hypotonic solution the lens A-P diameter returned to a value near its control level after an initial swell. This phenomenon was inhibited by chloride channel blockers. Conck~~sions We conclude that the lens fibre cells possess volume-activated Clchannels. A strong connection between these channels and lens swelling i6 indicated and their inhibition results in lens opacification, raising the possibilitv of a volume regulatory system involved in maintaining lens structure

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

Evalauation of Laminin Expression during Mouse Lens Development

Introduction: Among the components of the extracellular matrix (ECM) and basement membrane (BM), laminitis heterotrimeric glycoprotein (laminin) and collagen type IV are the most important. In a previous study we have examined the role of collagen type IV in the developing lens capsule. The present study aims to determine the appearance and distribution of laminin in the BM and ECM of lenses ...

متن کامل

Measurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer

  Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...

متن کامل

Evaluation of radiation absorption by thyroid gland and eye lens in trophy panoramic radiography

Evaluation of radiation absorption by thyroid gland and eye lens in trophy panoramic radiography Dr.AR. Talaee Pour *- Dr. S. Sahba ** - Dr. M. Maleknia***. *- Associate professor of Oral & Maxillofacial radiology Dept.- Faculty of Dentistry - Tehran University of Medical Sciences. ** - Associate professor of Oral Diseases and Diagnosis.- Faculty of Dentistry - Shaheed Beheshti University of Me...

متن کامل

Assessment of the Lens Anterior–Posterior Diameter as Compared with the Eye Globe by Ultrasonography in Rabbit

Objective- Assessment of the lens anterior – posterior (AP) diameter as compared with the eye globe by ultrasonography in rabbit.   Design- Descriptive study.   Animals- 120 male and female rabbits, two months to four years old, and weighting between 300 to 1500gr.   Procedures- 2D ultrasonography of the eyes was performed and AP diameter of the eyes and lens were measured using Sonosite Tit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Vision Research

دوره 35  شماره 

صفحات  -

تاریخ انتشار 1995