Effect of second-phase duration on the strength-duration relation for human transvenous defibrillation.

نویسندگان

  • S R Shorofsky
  • M R Gold
چکیده

BACKGROUND The mechanism by which biphasic waveforms improve defibrillation efficacy is unclear. In addition, the optimal shape of the biphasic waveforms remains controversial. Animal experiments suggest that prolonging the duration of the second phase longer than the first worsens defibrillation thresholds (DFT). The purpose of this study was to determine the strength-duration relation for the second phase of a biphasic defibrillation waveform in humans. METHODS AND RESULTS This was a prospective, randomized study of biphasic DFT in 36 patients; a uniform dual-coil transvenous lead system was used. In each patient, 3 DFTs were determined with the pulse duration for the second phase of the defibrillation waveform varying between 1 and 18 ms. The duration of the first phase was fixed at 6 ms and the capacitance was 150 microF. There was a significant increase in the leading edge voltage at DFT only when the second-phase pulse duration was decreased to 1 ms. There was no increase in DFT voltage even when the second-phase pulse duration was increased from 2 to 18 ms. Similar relations were observed for stored energy, leading edge current, or phase 2 energy. The normalized average current delivered during phase 2 decreased monotonically with increasing phase 2 duration. CONCLUSIONS In humans, the biphasic DFT voltage or energy is increased only when the second phase of the waveform is <2 ms. The DFT voltage is insensitive to increasing the second phase of the defibrillator waveform to as long as 18 ms, or 3 times the duration of the first phase of the waveform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of phase duration of biphasic waveforms on defibrillation energy requirements with a 70-microF capacitance.

BACKGROUND Phase duration of biphasic shocks may be an important determinant of defibrillation success. The purpose of this study was to investigate the effect of changing phase duration of biphasic pulses delivered by 70-microF capacitors on defibrillation energy requirements. This may be clinically relevant for the optimization of implantable cardioverter-defibrillator design and programming....

متن کامل

Strength-duration and probability of success curves for defibrillation with biphasic waveforms.

Certain biphasic waveforms require less energy to defibrillate than do monophasic pulses of equal duration, although the mechanisms of this increased effectiveness remain unclear. This study used strength-duration and percent success curves for defibrillation with monophasic and biphasic truncated exponential waveforms to explore these mechanisms. In part 1, defibrillation thresholds were deter...

متن کامل

Determining and Optimizing Effective Factors in Laser Irradiation on Skin Tensional Strength using a Hybrid DOE and DEA Approach

Introduction: We investigated the characteristic of a suitable irradiation on skin's tensional strength using design of experiments (DOE). The experiments in this research are designed in two phases and data envelopment analysis (DEA) is used for performance measurement of each phase. Material and Methods: Samples were provided from pleura as surface tissue made of collagen and elastin fibers. ...

متن کامل

Effect of massage Aromatherapy with lavandula on the duration of first and second stage of labor in nulliparous women

Introduction: Duration of labor and pain severity are main factors to fray pregnant women of vaginal delivery and acceptance for elective section. Hence, the purpose of this research was to investigate the effect of massage aromatherapy with lavandula in decreasing the duration of first and second stage of labor in nulliparous women. Methods: The present study is a clinical trial which performe...

متن کامل

Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.

A reduction in the shock strength required for defibrillation would allow use of a smaller automatic implantable cardioverter-defibrillator and would reduce the possibility of myocardial damage by the shock. Most internal defibrillation electrodes require 5 to 25 J for successful defibrillation in human beings and in dogs. In an attempt to lower the shock strength needed for defibrillation, we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 102 18  شماره 

صفحات  -

تاریخ انتشار 2000