The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacy.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Flow-diverter stents are emerging for the endovascular treatment of difficult-to-treat or otherwise untreatable cerebral aneurysms (wide-neck, fusiform, dissecting, blisterlike, or giant). We assessed the clinical safety and efficacy of the Flow-Redirection Endoluminal Device. MATERIALS AND METHODS This was an institutional review board-approved single-center observational clinical study in 29 patients with 34 aneurysms elected to be treated by endovascular intervention. After providing informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio <2 or neck diameter >4 mm, fusiform, dissecting, or giant aneurysms. The primary end point for clinical safety was the absence of death, absence of major or minor stroke, and absence of transient ischemic attack. The primary end point for treatment efficacy was complete angiographic occlusion according to the O'Kelly Marotta grading scale immediately after the procedure and at follow-up after 3 and 6 months (O'Kelly Marotta D: complete occlusion). RESULTS The Flow-Redirection Intraluminal Device deployment was technically successful in all cases. In 26/29 (89%) of patients, the primary end point of safety was reached; in the 3 remaining patients, 1 disabling ischemic stroke and 2 minor strokes with complete recovery at follow-up were observed. Angiographic (DSA and MRA) and clinical follow-up were available after 3 months in 29/29 (100%) and after 6 months in 25/29 (86%) patients (after 6 months, only MRA follow-up was performed according to our study protocol and institutional standard). At 3-month follow-up, complete occlusion was reached in 19/34 aneurysms (O'Kelly Marotta D: 19/34; 56%). At 6-month follow-up, aneurysm occlusion was complete in 22/30 aneurysms (O'Kelly Marotta D: 22/30; 73%). CONCLUSIONS Deployment of the Flow-Redirection Intraluminal Device flow-diverter stent is safe and effective in the treatment of difficult-to-treat or otherwise untreatable intracranial aneurysms.
منابع مشابه
Initial experience with implantation of novel dual layer flow-diverter device FRED
Flow-diverting stents can help treat complex and wide-necked cerebral aneurysms. The aim of the study was to evaluate initial experiences related to the safety and effectiveness of eight aneurysms treated with a new dual layer coverage designed flow-diverter device. In 2012 Fred flow-diverter devices were used to treat 8 unruptured wide neck (dome-neck ratio ≤ 1.5) and sidewall aneurysms in 6 p...
متن کاملParent artery reconstruction for large or giant cerebral aneurysms using a Tubridge flow diverter (PARAT): study protocol for a multicenter, randomized, controlled clinical trial
BACKGROUND The treatment of large (10-25 mm) or giant (≥25 mm) cerebral aneurysms remains technically challenging, with a much higher complication and recanalization rate than that is observed for smaller aneurysms. The use of a flow diverter seems to facilitate the treatment of this special entity. In a previous single-center prospective study approved by the Ethics Committee and China Food an...
متن کاملSurpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study.
BACKGROUND AND PURPOSE Incomplete occlusion and recanalization of large and wide-neck brain aneurysms treated by endovascular therapy remains a challenge. We present preliminary clinical and angiographic results of an experimentally optimized Surpass flow diverter for treatment of intracranial aneurysms in a prospective, multicenter, nonrandomized, single-arm study. MATERIALS AND METHODS At 2...
متن کاملTreatment of Intracranial Aneurysms with Flow Re-direction Endoluminal Device - A Single Centre Experience with Short-term Follow-up Results
PURPOSE A flow diverter (FD) is an effective treatment option for intracranial aneurysms. The Flow Re-direction Endoluminal Device (FRED) is a relatively new flow diverter with a unique dual-layer design. We report our experience and short-term results with the FRED. MATERIALS AND METHODS We did a retrospective review of all consecutive cases in which the FRED was used to treat intracranial a...
متن کاملHemodynamics investigation for a giant aneurysm treated by a flow diverter implantation.
Flow diverter is a kind of stent-like devices with higher metal coverage rate, and it is deployed endovascularly to treat cerebral aneurysms, especially to treat giant aneurysms. However, there exist some arguments about its safety and efficacy. Hemodynamics is considered to play very important role during the initiation, growth and rupture of cerebral aneurysms. In this study, the models of a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 36 6 شماره
صفحات -
تاریخ انتشار 2015