Biomechanics of low-modulus and standard acrylic bone cements in simulated vertebroplasty: A human ex vivo study.

نویسندگان

  • Ondrej Holub
  • Alejandro López
  • Vishal Borse
  • Håkan Engqvist
  • Nik Kapur
  • Richard M Hall
  • Cecilia Persson
چکیده

The high stiffness of bone cements used in vertebroplasty has been hypothesised to contribute to the propensity of adjacent vertebral fractures after treatment. Therefore, new low-modulus cements have been developed; however, there are currently no studies assessing the biomechanical aspects of vertebroplasty with these cements in an ex vivo non-prophylactic model. In this study, we induced wedge fractures through eccentric uniaxial compression to single whole-vertebrae, before and after augmentation with either standard or low-modulus cement. Compressive strength and stiffness of individual vertebrae were measured, on 19 samples from metastatic spines and 20 samples from elderly, osteopenic spines. While both cement types increased the strength of both the metastatic (+34% and +63% for standard and low-modulus cement, respectively) and the elderly vertebrae (+303% and +113%, respectively), none of them restored the initial stiffness of metastatic specimens (-51% and -46%, respectively). Furthermore, low-modulus cement gave a lower total stiffness (-13%) of elderly specimens whereas standard cement increased it above initial levels (+17%). Results show that vertebroplasty with low-modulus cement could provide restoration of the initial stiffness while increasing the strength of fractured elderly vertebrae and hence represent a treatment modality which is closer to pre-augmented behaviour. Also, this study indicates that stiffness-modified cement needs to be optimised for patient/pathology specific treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Article In Vitro and In Vivo Response to Low-Modulus PMMA-Based Bone Cement

The high stiffness of acrylic bone cements has been hypothesized to contribute to the increased number of fractures encountered after vertebroplasty, which has led to the development of low-modulus cements. However, there is no data available on the in vivo biocompatibility of any low-modulus cement. In this study, the in vitro cytotoxicity and in vivo biocompatibility of two types of low-modul...

متن کامل

In Vitro and In Vivo Response to Low-Modulus PMMA-Based Bone Cement

The high stiffness of acrylic bone cements has been hypothesized to contribute to the increased number of fractures encountered after vertebroplasty, which has led to the development of low-modulus cements. However, there is no data available on the in vivo biocompatibility of any low-modulus cement. In this study, the in vitro cytotoxicity and in vivo biocompatibility of two types of low-modul...

متن کامل

The effect of oligo(trimethylene carbonate) addition on the stiffness of acrylic bone cement

With the increasing elderly population an increase in the number of bony fractures associated to age-related diseases such as osteoporosis also follows. The relatively high stiffness of the acrylic bone cements used in these patients has been suggested to give raise to a suboptimal load distribution surrounding the cement in vivo, and hence contribute to clinical complications, such as addition...

متن کامل

Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty.

Acrylic bone cements are widely used for fixation of joint prostheses as well as for vertebral body augmentation procedures of vertebroplasty and balloon kyphoplasty, with the cement zone(s) being subjected to repeated mechanical loading in each of these applications. Although, in vertebroplasty and balloon kyphoplasty, the cement zone is exposed to mainly cyclical compressive load, the compres...

متن کامل

Bone marrow modified acrylic bone cement for augmentation of osteoporotic cancellous bone.

The use of polymethylmethacrylate (PMMA) cement to reinforce fragile or broken vertebral bodies (vertebroplasty) leads to extensive bone stiffening. This might be one reason for fractures at the adjacent vertebrae following this procedure. PMMA with a reduced Young's modulus may be more suitable. The goal of this study was to produce and characterize PMMA bone cements with a reduced Young's mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 48 12  شماره 

صفحات  -

تاریخ انتشار 2015