Peripheral venous pressure waveform.
نویسندگان
چکیده
PURPOSE OF REVIEW The focus of intraoperative monitoring is moving away from invasive monitoring. This has been attributed to procedure time, cost, and the known risks, which include carotid artery puncture, arrhythmia, pneumothorax, and infection. Until recently, the venous system's contribution to the circulatory system has been incorrectly identified as being insignificant. This article summarizes the unique characteristics of the peripheral venous system. RECENT FINDINGS Numerous studies done in the last few years have paid attention to peripheral venous pressure and more specifically its pressure waveform. The popularity of, and further focus on, the field of photoplethysmography has described a strong venous component. Analysis of venous waveforms has indicated that, like arterial waveforms, they too exhibit respiratory variations and change in response to physiologic challenges. SUMMARY The veins play a critical role in cardiovascular homeostasis; they do more than conduct blood to the heart. Considering the ease of measurement from a peripheral intravenous catheter, further study should be conducted to investigate the usefulness and limitations of such a minimally invasive and inexpensive monitoring device.
منابع مشابه
CARDIOVASCULAR MEDICINE Quantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform
Objective: To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. Design: Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104–0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...
متن کاملThe relationship between arterial transducer level and pulse contour waveform-derived measurements
For hemodynamic monitoring, the pressure transducer is suggested to be fixed at the level of the phlebostatic axis in critically ill patients [1,2]. The correction and adjustment of pressure transducer are emphasized in central venous pressure monitoring in clinical practice. The exact position of the transducer is relatively easy to be ignored for invasive arterial blood pressure monitoring [3...
متن کاملQuantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform.
OBJECTIVE To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. DESIGN Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104-0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...
متن کاملDoes the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?
BACKGROUND Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The...
متن کاملReal-Time Analysis of Intracranial Pressure Waveform Morphology
The cranial vault is composed of four fundamental components: arterial blood, venous blood, cerebrospinal fluid (CSF), and brain parenchyma. Intracranial pressure (ICP) represents the pressure within the brain parenchyma and cerebrospinal fluid (CSF). The environment within the cranial vault is unique compared to other organ systems; it is enclosed within a rigid skull and thus small volumetric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Current opinion in anaesthesiology
دوره 22 6 شماره
صفحات -
تاریخ انتشار 2009