The importance of the implant quality in APBI – Gliwice experience. Dosimetric evaluation
نویسندگان
چکیده
This study includes four years of our clinical trials to improve implant quality in multicatheter accelerated partial breast irradiation (APBI). The progress in dosimetric and volumetric parameters of the treatment plans was evaluated. One hundred and ninety-one women, for whom treatment plans were made based on three dimensional imaging, were selected for the study. To evaluate progress made in our APBI procedure, following parameters and indices were taken into account: percentage of the target volume receiving the reference dose (PTVref), minimum dose in the target volume expressed as a percentage of reference dose (PTVmin), dose homogeneity index (DHI), and conformity index (COIN). Additionally, the plan quality index was calculated for every group as the sum of mean values of four evaluated parameters. PTVref have increased from the mean value of 83.4% at the beginning to recent 94.8%. The maximum value equals to 95.4%. The same trend can be observed with PTVmin value, which has been improved from 51.7% to 70.1%, maximally. DHI and COIN mean values present similar progress. DHI value increased from 0.53 level to 0.68, and COIN from 0.58 in 2009 to 0.74. Plan quality index has increased from 2.46 in 2009 to 3.06, recently. The implant quality is crucial for the accurate dose distribution. This paper shows the progress that was made in APBI procedure to improve implant quality. Nowadays, our implant technique is based on three-dimensional CT imaging results in acceptable dose distributions.
منابع مشابه
Multi-catheter interstitial brachytherapy for partial breast irradiation: an audit of implant quality based on dosimetric evaluation comparing intra-operative versus post-operative placement
PURPOSE The use of multicatheter interstitial brachytherapy (MIB) for accelerated partial breast irradiation (APBI) in early breast cancer (EBC) patients outside the trial setting has increased. Hence, there is a need to critically evaluate implant quality. Moreover, there is a scarcity of reports using an open cavity technique. We report the dosimetric indices of open and closed cavity MIB tec...
متن کاملDosimetrical Evaluation and Clinical Implementation of a Strut-adjusted-volume-implant Savi Device Used for Accelerated Partial Breast Irradiation
The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target v...
متن کاملDosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
PURPOSE Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosme...
متن کاملDosimetric and radiobiological evaluation of Accelerated Partial Breast Irradiation Techniques
Accelerated Partial Breast Irradiation (APBI) decreases the duration of entire radiotherapy course (Sanders ME et al 2007). The reduced treatment volume makes APBI more appealing to both clinicians and patients. The uses of brachytherapy either as HDR or LDR interstitial implants have shown promising results which are obvious from the published research works (Arthur DW et al 2003; Baglan KL et...
متن کاملAccelerated partial breast irradiation using the strut-adjusted volume implant single-entry hybrid catheter in brachytherapy for breast cancer in the setting of breast augmentation.
PURPOSE Accelerated partial breast irradiation (APBI) has gained popularity as an alternative to adjuvant whole breast irradiation; however, owing to limitations of delivery devices for brachytherapy, APBI has not been a suitable option for all the patients. This report evaluates APBI using the strut-adjusted volume implant (SAVI) single-entry catheter to deliver brachytherapy for breast cancer...
متن کامل