Particle size study of nine metered dose inhalers, and their deposition probabilities in the airways.
نویسندگان
چکیده
This study deals with the particle size measurement of nine aerosol metered dose inhalers. Calibration was made possible by the use of a laser particle velocimeter (aerodynamic Particle Sizer from TSI). The count median aerodynamic diameters (CMAD) show little variation, from 0.63 to 0.73 micron, with standard deviations (sigma g) between 1.2 and 1.8. Aerodynamic diameter aerosol diagram analysis showed multimodal mass distribution for all the tested dose inhalers. Calculations for the airway deposition probabilities (extrathoracic, tracheobronchial and alveolar) refer to the studies made by W. Stahlhofen and co-workers. As most aerosol metered dose inhalers have a predominantly bronchial therapeutic destination, the deposition at the bronchial level could be enhanced with the following parameters: inspired volume of 1500 ml, inspiratory time of 2 sec, aerosol mass median aerodynamic diameter (MMAD) of 7.5 microns, with a monodispersed distribution. The respective influences of the excipients and propellents used for the aerosolization of these dose metered inhalers are also discussed.
منابع مشابه
Usage Pattern, Satisfaction, Causes of Concern and Related Factors of Metered Dose Inhalers in Children with Asthma, the Parents Perspective
Introduction Metered Dose Inhalers (MDIs) are the most common drugs for the control of asthma. This study was conducted to evaluate usage patterns, satisfaction with and concerns about MDIs for children with asthma and the related factors from the viewpoints’ of their parents. Materials and methods This cross-sectional study was conducted on children with asthma who referred to asthma and a...
متن کاملAirway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers.
Many different metered-dose inhalation devices are becoming available for the treatment of airway diseases. Each of these inhalers differs in its delivery characteristics. An assessment of the efficacy of drug delivery by these inhalers is essential, in view of their therapeutic use. A review of the literature on the relationship between airway deposition and airway effects of drugs delivered f...
متن کاملMicron particle deposition in a tracheobronchial airway model under different breathing conditions.
Effective management of asthma is dependent on achieving adequate delivery of the drugs into the lung. Inhalers come in the form of dry powder inhalers (DPIs) and metered dose inhalers (pMDIs) with the former requiring a deep fast breath for activation while there are no restrictions on inhalation rates for the latter. This study investigates two aerosol medication delivery methods (i) an ideal...
متن کاملAsthma medication delivery: mists and myths.
Asthma is usually treated with inhaled corticosteroids (ICS) and bronchodilators generated from pressurized metered dose inhalers (pMDI), dry powder inhalers (DPI), or nebulizers. The target areas for ICS and beta 2-agonists in the treatment of asthma are explained. Drug deposition not only depends on particle size, but also on inhalation manoeuvre. Myths regarding inhalation treatments lead to...
متن کاملComputational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology.
The popular pressurized metered dose inhaler (pMDI), especially for asthma treatment, has undergone various changes in terms of propellant use and valve design. Most significant are the choice of hydrofluoroalkane-134a (HFA-134a) as a new propellant (rather than chlorofluorocarbon, CFC), a smaller exit nozzle diameter and attachment of a spacer in order to reduce ultimately droplet size and spr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 1 6 شماره
صفحات -
تاریخ انتشار 1988