COBAS AmpliPrep-COBAS TaqMan hepatitis B virus (HBV) test: a novel automated real-time PCR assay for quantification of HBV DNA in plasma.

نویسندگان

  • Tiziano Allice
  • Francesco Cerutti
  • Fabrizia Pittaluga
  • Silvia Varetto
  • Silvia Gabella
  • Alfredo Marzano
  • Alessandro Franchello
  • Giuseppe Colucci
  • Valeria Ghisetti
چکیده

Success in antiviral therapy for chronic hepatitis B is supported by highly sensitive PCR-based assays for hepatitis B virus (HBV) DNA. Nucleic acid extraction from biologic specimens is technically demanding, and reliable PCR results depend on it. The performances of the fully automatic system COBAS AmpliPrep-COBAS TaqMan 48 (CAP-CTM; Roche, Branchburg, NJ) for HBV DNA extraction and real-time PCR quantification were assessed and compared to the endpoint PCR COBAS AMPLICOR HBV monitor (CAHBM; Roche). Analytical evaluation with a proficiency panel showed that CAP-CTM quantitated HBV DNA levels in one single run over a wide dynamic range (7 logs) with a close correlation between expected and observed values (r = 0.976, interassay variability below 5%). Clinical evaluation, as tested with samples from 92 HBsAg-positive patients, demonstrated excellent correlation with CAHBM (r = 0.966, mean difference in quantitation = 0.36 log(10) IU/ml). CAP-CTM detected 10% more viremic patients and longer periods of residual viremia in those on therapy. In lamivudine (LAM)-resistant patients, the reduction of HBV DNA after 12 months of Adefovir (ADF) was higher in the combination (LAM+ADF) schedule than in ADF monotherapy (5.1 logs versus 3.5 logs), suggesting a benefit in continuing LAM. CAP-CTM detected HBV DNA in liver biopsy samples from 15% of HBsAg-negative, anti-HBcAg-positive graft donors with no HBV DNA in plasma. The amount of intrahepatic HBV DNA was significantly lower in occult HBV infection than in overt disease. CAP-CTM can improve the management of HBV infection and the assessment of antiviral therapy and drug resistance, supporting further insights in the emerging area of occult HBV infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Cobas AmpliPrep/Cobas TaqMan real-time PCR assay for hepatitis B virus DNA quantification.

Hepatitis B virus (HBV) DNA quantification is used to establish the prognosis of chronic HBV-related liver disease, to identify those patients who need to be treated, and to monitor the virologic response and resistance to antiviral therapies. Real-time PCR-based assays are gradually replacing other technologies for routine quantification of HBV DNA in clinical practice. The goal of this study ...

متن کامل

Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification.

The performance characteristics of four different assays for hepatitis B virus (HBV) quantification were assessed: the Abbott RealTime HBV IUO, the Roche Cobas AmpliPrep/Cobas TaqMan HBV test, the Roche Cobas TaqMan HBV test with HighPure system, and the Qiagen artus HBV TM ASR. Limit of detection (LOD), linear range, reproducibility, and agreement were determined using a serially diluted plasm...

متن کامل

An in-house real-time polymerase chain reaction: standardisation and comparison with the Cobas Amplicor HBV monitor and Cobas AmpliPrep/Cobas TaqMan HBV tests for the quantification of hepatitis B virus DNA.

This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fif...

متن کامل

Performance of version 2.0 of the Cobas AmpliPrep/Cobas TaqMan real-time PCR assay for hepatitis B virus DNA quantification.

The detection and quantification of hepatitis B virus (HBV) DNA are essential for the diagnosis and treatment of chronic HBV infection. The use of real-time PCR assays for HBV DNA quantification is strongly recommended. The goal of this study was to evaluate the intrinsic characteristics and clinical performance of version 2.0 (v2.0) of the Cobas AmpliPrep/Cobas TaqMan (CAP/CTM) assay, a fully ...

متن کامل

Comparison of the Cobas Ampliprep/Cobas TaqMan HBV Test versus the Cobas Amplicor HBV monitor for HBV-DNA detection and quantification during antiviral therapy.

Performances of the new automatic system COBAS AmpliPrep/COBAS TaqMan 48 (CAP/CTM) (Roche, Branchburg, NJ) for HBV DNA extraction and real-time PCR quantification were assessed and compared with the endpoint PCR COBAS AMPLICOR HBV Monitor (CAHBM, Roche). Analytical evaluation with proficiency panels from UK National External Quality Assessment Scheme (UK NEQAS) over a 1-year period of distribut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 3  شماره 

صفحات  -