Measuring MEG closer to the brain: Performance of on-scalp sensor arrays

نویسندگان

  • Joonas Iivanainen
  • Matti Stenroos
  • Lauri Parkkonen
چکیده

Optically-pumped magnetometers (OPMs) have recently reached sensitivity levels required for magnetoencephalography (MEG). OPMs do not need cryogenics and can thus be placed within millimetres from the scalp into an array that adapts to the individual head size and shape, thereby reducing the distance from cortical sources to the sensors. Here, we quantified the improvement in recording MEG with hypothetical on-scalp OPM arrays compared to a 306-channel state-of-the-art SQUID array (102 magnetometers and 204 planar gradiometers). We simulated OPM arrays that measured either normal (nOPM; 102 sensors), tangential (tOPM; 204 sensors), or all components (aOPM; 306 sensors) of the magnetic field. We built forward models based on magnetic resonance images of 10 adult heads; we employed a three-compartment boundary element model and distributed current dipoles evenly across the cortical mantle. Compared to the SQUID magnetometers, nOPM and tOPM yielded 7.5 and 5.3 times higher signal power, while the correlations between the field patterns of source dipoles were reduced by factors of 2.8 and 3.6, respectively. Values of the field-pattern correlations were similar across nOPM, tOPM and SQUID gradiometers. Volume currents reduced the signals of primary currents on average by 10%, 72% and 15% in nOPM, tOPM and SQUID magnetometers, respectively. The information capacities of the OPM arrays were clearly higher than that of the SQUID array. The dipole-localization accuracies of the arrays were similar while the minimum-norm-based point-spread functions were on average 2.4 and 2.5 times more spread for the SQUID array compared to nOPM and tOPM arrays, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements.

Limitations of traditional magnetoencephalography (MEG) exclude some important patient groups from MEG examinations, such as epilepsy patients with a vagus nerve stimulator, patients with magnetic particles on the head or having magnetic dental materials that cause severe movement-related artefact signals. Conventional interference rejection methods are not able to remove the artefacts originat...

متن کامل

Measurement of brain function in pre-school children using a custom sized whole-head MEG sensor array.

OBJECTIVE Conventional whole-head MEG systems have fixed sensor arrays designed to accommodate most adult heads. However arrays optimised for adult brain measurements are suboptimal for research with the significantly smaller heads of young children. We wished to measure brain activity in children using a novel whole-head MEG system custom sized to fit the heads of pre-school-aged children. M...

متن کامل

Similarities and differences between on - scalp and

The development of new magnetic sensor technologies that promise sensitivities approaching that of conventional MEG technology while operating at far lower operating temperatures has catalysed the growing field of on-scalp MEG. The feasibility of on-scalp MEG has been demonstrated via benchmarking of new sensor technologies performing neuromagnetic recordings in close proximity to the head surf...

متن کامل

Similarities and differences between on-scalp and conventional in-helmet magnetoencephalography recordings

The development of new magnetic sensor technologies that promise sensitivities approaching that of conventional MEG technology while operating at far lower operating temperatures has catalysed the growing field of on-scalp MEG. The feasibility of on-scalp MEG has been demonstrated via benchmarking of new sensor technologies performing neuromagnetic recordings in close proximity to the head surf...

متن کامل

THESIS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY Development of high-T c SQUID magnetometers for on-scalp MEG

This thesis describes the development of high critical temperature superconducting quantum interference device (high-Tc SQUID) magnetometers based on bicrystal grain boundary and nanowire junctions for the potential use in on-scalp magnetoencephalography (MEG), which is a new generation MEG technique with reduced sensor-to-subject standoff distances. MEG is a method of mapping neural dynamics i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 147  شماره 

صفحات  -

تاریخ انتشار 2017