Evaluation ofThree First-Generation I -Selective Electrode Analyzers for Lithium: Systematic Errors, Frequency of Random Interferences, and Recommendations Based on Comparison with Flame Atomic Emission Spectrometry

نویسنده

  • Anthony
چکیده

Ion-selective electrode analyzers for measuring lithium (Lu ISE) in serum became available in early 1987. We compared results for patients’ samples from three of them vs results from flame atomic emission spectrometry (FAES). Within-run and day-to-day imprecision ranged from 0.01 to 0.03 mmol/L and 0.01 to 0.04 mmol/L, respectively. Comparing U/ISE results ( with the FAES results (x) gave the following equations: y = 1.063x 0.035 for AMDEV’s Lytening 2, y = 1.020x + 0.038 for NOVA’s Model 11, and y = 1.030x 0.027 for AVL’s Model 985. Unexplained positive errors >0.2 mmol/L were observed for two of the 90 patients’ samples, but only a few additional excessively high values were seen in 3000 patients’ samples run subsequently (Lytening 2). Causes of error in clinical Li/ISE measurements are still unclear; simply characterizing them as “matrix effects” does not correct the underlying analytical problem. An increase in pH from loss of CO2 gave low results on two of the three Li/ISE analyzers but did not change FAESresults. Trimethylammonium bicarbonate used in a reconstitution solution caused extremely high Li/ISE results but did not change FAES results. Performance specifications to help reduce and correct these errors are recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lithium determinations evaluated in eight analyzers.

We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by drugs (procainamide, N-acetylprocainamide, quinidine, lidocaine, carbamazepine, ...

متن کامل

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Determination of serum lithium: comparison between atomic emission and absorption spectrometry methods

Introduction: The therapeutic monitoring of lithium, through concentration measurements, is important for individual dose adjustment, as a marker of treatment adherence and to prevent poisoning and side effects. Objectives: Validate and compare two methods – atomic emission and atomic absorption – for the determination of lithium in serum samples. Methodology: Parameters such as specificity, pr...

متن کامل

Determination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore

Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004