Evaluation of a second-generation LED curing light.

نویسندگان

  • Richard B T Price
  • Corey A Felix
  • Pantelis Andreou
چکیده

BACKGROUND Light-emitting diode (LED) curing lights offer advantages over quartz-tungsten-halogen (QTH) lights, but the first-generation LED lights had some disadvantages. PURPOSE This study compared a second-generation LED light with a QTH light to determine which was better at photopolymerizing a variety of resin composites. METHODS The ability of a LED light used for 20 and 40 seconds to cure 10 resin composites was compared with that of a QTH light used for 40 seconds. The composites were 1.6 mm thick and were irradiated at distances of 2 and 9 mm from the light guide. The Knoop hardness at the top and the bottom of each composite was measured at 15 minutes and 24 hours after irradiation. RESULTS The different curing lights and irradiation times did not have the same effect on all of the composites (p < 0.01). For specimens analyzed 24 hours after irradiation, the LED light used for 20 seconds cured 5 of the composites as well as when the QTH light was used for 40 seconds (p > 0.01). When used for 40 seconds, the LED light cured 6 of the composites as well as when the QTH light was used (p > 0.01), and all 10 composites achieved more than 80% of the hardness produced with the QTH light. CONCLUSIONS This LED light could not polymerize all of the composites as well as the QTH light. However, when used for 40 seconds, it cured more than half of the composites as well as when the QTH light was used, and all of the composites achieved a hardness comparable to that produced with the QTH light.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of Exposure Times and Light Curing Sources on Surface Micro-Hardness of a Resin Modified Glass Ionomer

Introduction: The aim of this study was to evaluate the influenceof different light curing systems and curing times on the micro-hardness of aresin modified glass ionomer. Methods: Forty two samples of ResinModified Glass Ionomer (RMGI) were prepared using stainless steel cylindrical mold(8 × 2 mm) and randomly divided into six groups of seven. Three groups werecured with a Quartz Tungsten Halo...

متن کامل

Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units

OBJECTIVE With the introduction of third-generation light-emitting diodes (LEDs) in dental practice, it is necessary to compare their bracket-bonding effects, safety, and efficacy with those of the second-generation units. METHODS In this study, 80 extracted human premolars were randomly divided into eight groups of 10 samples each. Metal or polycrystalline ceramic brackets were bonded on the...

متن کامل

Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources

OBJECTIVES To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). METHODS A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was use...

متن کامل

Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT

Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...

متن کامل

Comparison of the heat generation of light curing units.

AIM The aim of this study was to evaluate the heat generation of three different types of light curing units. METHODS AND MATERIALS Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal

دوره 69 10  شماره 

صفحات  -

تاریخ انتشار 2003