Pressure vs flow triggering during pressure support ventilation.

نویسندگان

  • R Goulet
  • D Hess
  • R M Kacmarek
چکیده

BACKGROUND Adult mechanical ventilators have traditionally been pressure- or time-triggered. More recently, flow triggering has become available and some adult ventilators allow the choice between pressure or flow triggering. Prior studies have supported the superiority of flow triggering during continuous positive airway pressure, but few have compared pressure and flow triggering during pressure support ventilation (PSV). The purpose of this study was to compare pressure and flow triggering during PSV in adult mechanically ventilated patients. METHODS The study population consisted of 10 adult patients ventilated with a mechanical ventilator (Nellcor-Puritan-Bennett 7200ae) in the PSV mode. In random order, we compared pressure triggering of -0.5 H2O, pressure triggering -1 cm H2O, flow triggering of 5/2 L/min, and flow triggering 10/3 L/min. Pressure was measured for 5 min at the proximal endotracheal tube using a data acquisition rate of 100 Hz. From the airway pressure signal, trigger pressure (deltaP) was defined as the difference between positive end-expiratory pressure (PEEP) and the maximum negative deflection prior to onset of the triggered breath. Pressure-time product (PTP) was defined as the area produced by the pressure waveform below PEEP during onset of the triggered breath. Trigger time (deltaT) was defined as the time interval below PEEP during onset of the triggered breath. RESULTS A pressure trigger of -0.5 cm H2O was significantly more sensitive than the other trigger methods for deltaP, PTP, and deltaT (p<0.001). There was also a significant difference between patients for deltaP, deltaT, and PTP for each trigger method (p<0.001). CONCLUSIONS For this group of patients, flow triggering was not superior to pressure triggering at -0.5 cm H2O during PSV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different inspiratory triggering settings in automated ventilators during cardiopulmonary resuscitation in a porcine model

BACKGROUND Mechanical ventilation via automated in-hospital ventilators is quite common during cardiopulmonary resuscitation. It is not known whether different inspiratory triggering sensitivity settings of ordinary ventilators have different effects on actual ventilation, gas exchange and hemodynamics during resuscitation. METHODS 18 pigs enrolled in this study were anaesthetized and intubat...

متن کامل

A noninvasive method to identify ineffective triggering in patients with noninvasive pressure support ventilation.

BACKGROUND Ineffective inspiratory triggering efforts are a major cause of poor patient-ventilator interactions during mechanical ventilation, but their routine identification requires the insertion of an esophageal catheter. OBJECTIVES We developed a mathematical analysis of ventilatory tracings recorded under noninvasive pressure ventilation in order to identify ineffective triggering effor...

متن کامل

A Comparative Study of Treatment Response of Respiratory Distress Syndrome in Preterm Infants: Early Nasal Intermittent Positive Pressure Ventilation versus Early Nasal Continuous Positive Airway Pressure

Background Infant respiratory distress syndrome (IRDS) is one of the main causes of serious complications and death in preterm infants. Both Nasal Continuous Positive Airway Pressure (NCPAP) and Nasal Intermittent Positive Pressure Ventilation (NIPPV) are known as the most common treatment strategies for IRDS. The present study intended to compare NCPAP and NIPPV in the treatment of preterm inf...

متن کامل

Physiological effects of flow and pressure triggering during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease.

BACKGROUND The effect of the type of trigger system on inspiratory effort has been studied in intubated patients, but no data are available in non-invasive mechanical ventilation where the "trigger variable" may be even more important since assisted modes of ventilation are often employed from the beginning of mechanical ventilation. METHODS The effect of flow triggering (1 and 5 1/min) and p...

متن کامل

Estimation of triggering work of breathing. The dependence on lung mechanics and bias flow during pressure support ventilation.

Work of breathing necessary to trigger a ventilator (WOBtr) was calculated during pressure support ventilation (PSV), and the effect of bias flow on WOBtr was evaluated. A spring-loaded bellows type lung model with two bellows placed in series was used to simulate spontaneous breathing. A Venturi mechanism of jet flow generated subatmospheric pressure inside the diaphragm bellows simulated insp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 111 6  شماره 

صفحات  -

تاریخ انتشار 1997