SKGEL® Implant Versus T-Flux® Implant in the Contralateral Eye in Deep Sclerectomy with Phacoemulsification: Long-Term Follow-Up

نویسندگان

  • Frank Schreyger
  • Gabor Scharioth
  • Holger Baatz
چکیده

PURPOSE To intraindividually compare the efficacy and safety of the SKGEL(®) implant versus the T-Flux(®) implant in deep sclerectomy. METHODS In a retrospective analysis 17 patients were identified who underwent combined phacoemulsification-deep sclerectomy and implantation of SKGEL(®) in one eye and T-Flux(®) in the contralateral eye. RESULTS In eyes with SKGEL(®) the IOP decreased from 20.6+7.3 mm Hg to 14.8+5.3 mm Hg (-5.8 mm Hg or -28.1%), and in eyes with T-Flux(®) from 19.9+7.2 mm Hg to 14.7+3.3 mm Hg (-5.2 mm Hg or -26.1%, no statistically significant difference, p >0.05). Antiglaucoma medications with either implant decreased from initially 2.0+0.8 to 0.3+0.7. A qualified success was found in 17/17 eyes with T-Flux(®) and in 16/17 eyes with SKGEL(®). Complete success was achieved in 14/17 eyes with T-Flux(®) and in 13/17 eyes with SKGEL(®). CONCLUSIONS The IOP-lowering effect and safety of SKGEL(®) and T-Flux(®) seem to be comparable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five-year experience with non penetrating deep sclerectomy.

PURPOSE To assess the long-term safety and effectiveness of non penetrating deep sclerectomy (DS) and to compare the incidence and the severity of postoperative complications and the IOP results according to surgical adjuvants (implant device, antimetabolite or both) were used or not. MATERIAL-METHODS Retrospective non randomised study including 171 eyes (136 patients), mean age: 63.9 years) ...

متن کامل

Comparative study between deep sclerectomy with and without collagen implant: long term follow up.

AIM To identify the value of using collagen implant in deep sclerectomy. METHODS A prospective randomised trial of 104 eyes (104 patients) with medically uncontrolled primary and secondary open angle glaucoma. All patients had deep sclerectomy (DS), half of them with and the other half without a collagen implant (CI) sutured in the scleral bed. The main outcome measures were intraocular press...

متن کامل

Deep Sclerectomy with Nonabsorbable Implant (T-Flux) in Patients with Pseudoexfoliation Glaucoma

Purpose. To evaluate the effectiveness of deep sclerectomy with T-flux implant (DS T-flux) in patients with pseudoexfoliation glaucoma (PExG). Methods. 20 eyes of 18 patients with medically uncontrolled PExG have undergone DS T-flux implantation. Postoperatively we evaluated the IOP values and the frequency of complications. The minimum follow-up time was 12 months (20 eyes) and the maximum 24 ...

متن کامل

Supraciliary Hema Implant in Combined Deep Sclerectomy and Phacoemulsification: One Year Results

We present the combined surgery of non-penetrating deep sclerectomy with insertion of the implant in the supraciliary space as an effective and safe surgery for patients with both cataract and primary open angle glaucoma. This study included 20 eyes of 16 patients who were followed up during 12 months. We found a significant intraocular pressure reduction, changing from a preoperative mean of 2...

متن کامل

Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up

PURPOSE To describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome and the anatomic characteristics of filtering blebs, using anterior segment optical coherence tomography (AS-OCT). METHODS A prospective case-series study was conducted in five eyes (5 patients) with open angle glaucoma. The fornix-based deep sclerectomy with Esnoper-Clip® implant wa...

متن کامل