Semi-automatic Reference Standard Construction for Quantitative Evaluation of Lung CT Registration
نویسندگان
چکیده
An algorithm is presented for the efficient semi-automatic construction of a detailed reference standard for registration in thoracic CT. A well-distributed set of 100 landmarks is detected fully automatically in one scan of a pair to be registered. Using a custom-designed interface, observers locate corresponding anatomic locations in the second scan. The manual annotations are used to learn the relationship between the scans and after approximately twenty manual marks the remaining points are matched automatically. Inter-observer differences demonstrate the accuracy of the matching and the applicability of the reference standard is demonstrated on two different sets of registration results over 19 CT scan pairs.
منابع مشابه
Registration uncertainties between 3D cone beam computed tomography and different reference CT datasets in lung stereotactic body radiation therapy
BACKGROUND The aim of this study was to analyze differences in couch shifts (setup errors) resulting from image registration of different CT datasets with free breathing cone beam CTs (FB-CBCT). As well automatic as manual image registrations were performed and registration results were correlated to tumor characteristics. METHODS FB-CBCT image registration was performed for 49 patients with ...
متن کاملIndividual virtual phantom reconstruction for organ dosimetry based on standard available phantoms
Background: In nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. Monte Carlo simulation and phantoms have been used in many works before. The shape, size and volume in organs are varied, and this variation will produce error in dose calculation if no correction is applied. Materials and Methods: A computational framewo...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملValidating Point-based MR/CT Registration Based on Semi-automatic Landmark Extraction
Manually extracting 3D anatomical point landmarks from images is generally timeconsuming and usually lacks reproducibility. To improve on this, we developed a semiautomatic procedure for landmark extraction. In this paper, we report on the validation of our procedure for the case of point-based rigid registration of MR/CT head images. The results of our semi-automatic procedure are compared wit...
متن کاملValidation of simplified dosimetry approaches in ⁸⁹Zr-PET/CT: the use of manual versus semi-automatic delineation methods to estimate organ absorbed doses.
PURPOSE Increasing interest in immuno-positron emission tomography (PET) studies requires development of dosimetry methods which will provide accurate estimations of organ absorbed doses. The purpose of this study is to develop and validate simplified dosimetry approaches for (89)Zirconium-PET (Zr-PET)/computed tomography (CT) studies. METHODS Five patients with advanced colorectal cancer rec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 11 Pt 2 شماره
صفحات -
تاریخ انتشار 2008