Performance Improvement of Total Ionization Dose Radiation Sensor Devices Using Fluorine-Treated MOHOS
نویسندگان
چکیده
Fluorine-treated titanium nitride-silicon oxide-hafnium oxide-silicon oxide-silicon devices (hereafter F-MOHOS) are candidates for total ionization dose (TID) radiation sensor applications. The main subject of the study reportedherein is the performance improvement in terms of TID radiation-induced charge generation effect and charge-retention reliability characterization for F-MOHOS devices. In the case of F-MOHOS TID radiation sensors, the gamma radiation induces a significant decrease of threshold voltage VT and the radiation-induced charge density is nearly six times larger than that of standard metal-oxide-nitride-oxide-silicon MONOS devices. The decrease of VT for F-MOHOS after gamma irradiation has a strong correlation to the TID up to 5 Mrad gamma irradiation as well. The improvement of charge retention loss for F-MOHOS devices is nearly 15% better than that of metal-oxide-hafnium oxide-oxide-silicon MOHOS devices. The F-MOHOS device described in this study demonstrates better feasibility for non-volatile TID radiation sensing in the future.
منابع مشابه
An Ionizing Radiation Sensor Using a Pre-Programmed MAHAOS Device
Metal-aluminum oxide-hafnium aluminum oxide-silicon oxide-silicon (hereafter MAHAOS) devices can be candidates for ionizing radiation sensor applications. In this work, MAHAOS devices (SONOS-like structures with high k stack gate dielectric) were studied regarding the first known characterization of the ionization radiation sensing response. The change of threshold voltage V(T) for a MAHAOS dev...
متن کاملساخت فیلم پلی وینیل کلرید آلاییده شده با کوئیناکرین دی هیدروکلرید و مطالعه ویژگیهای دزیمتری آن
Ionization radiation induced decomposition of dyes is a concept frequently exploited to develop devices to measure the radiation dose. In this study, using this concept, preparation of polyvinyl chloride films doped with different amounts of quinacrine dihydrochloride were done and their capabilities for dosimetry of gamma radiation doses in the range of 0 to 60 kGy were evaluated. The results ...
متن کاملIn vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)
Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...
متن کاملامکان سنجی بکارگیری عناصر نیمه هادی از نوع PIN به منظور دزیمتری پرتوهای ایکس تشخیصی
Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...
متن کاملRadiation Effects on the On-line Monitoring System of a Hadrontherapy Center
Introduction Today, there is a growing interest in the use of hadrontherapy as an advanced radiotherapy technique. Hadrontherapy is considered a promising tool for cancer treatment, given its high radiobiological effectiveness and high accuracy of dose deposition due to the physical properties of hadrons. However, new radiation modalities of dose delivery and on-line beam monitoring play crucia...
متن کامل