Comparison of trace element concentration in bone and intervertebral disc tissue by atomic absorption spectrometry techniques

نویسندگان

  • Łukasz Kubaszewski
  • Anetta Zioła-Frankowska
  • Marcin Frankowski
  • Piotr Rogala
  • Zuzanna Gasik
  • Jacek Kaczmarczyk
  • Andrzej Nowakowski
  • Mikolaj Dabrowski
  • Wojciech Labedz
  • Grzegorz Miękisiak
  • Robert Gasik
چکیده

BACKGROUND Trace element (TE) analysis in human tissue has the dual purpose of assessing environmental pollution and metabolism. In literature, bone TE analysis is common, but studies in intervertebral disc (IVD) tissue are lacking. The aim of the study was evaluation of the difference of TE concentration in intervertebral disc and bone in patients with degenerative changes. The comparison of the tissues differing in metabolism, blood perfusion, or separateness from adjoining tissues but playing similar biomechanical role and presenting some common morphological traits may shed new light on metabolism nuances, degenerative process, as well as accumulation potential of IVD in respect to bone. METHODS In the study, we analyzed two types of samples: intervertebral disc (n =30, from 22 patients operated due to degenerative disc disease) and femoral bone (n =26, separately femoral head and neck, from 26 patients, acquired in total hip arthroplasty procedure in course of idiopathic osteoarthritis of the hip joint). In the samples we analyzed, with atomic absorption spectrometry, the concentrations of Pb, Ni, Mo, Cu, Mg, and Zn. RESULTS The element concentrations identified in bone are comparable to those presented in the literature. In the case of Pb, Ni, Mo, Mg, and Zn, the concentration in the bone was 2 to 25.8 times higher than that observed in the disc. Only the Cu concentration was higher in disc tissue than in bone. In disc tissue, fewer samples had TE concentrations below the detection threshold. We found significant differences in TE profiles in the compared tissues. CONCLUSIONS The results show that the disc could serve as a more stable compartment for evaluating TE concentration, especially for TEs that are environmentally related.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atomic Absorption Spectrometry Analysis of Trace Elements in Degenerated Intervertebral Disc Tissue

BACKGROUND Few studies have investigated trace elements (TE) in human intervertebral disc (IVD) tissue. Trace element presence can have diverse meanings: essential TE show the metabolic modalities of the tissue, while environmentally-related TE indicate pollution and tissue-specific absorption and accumulation. IVD is a highly specific compartment with impaired communication with adjacent bone....

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014