• GEM10P4/CFG-PV4/DWR-30 Coaxial Detector System (Includes detector, cryostat, dewar, preamplifier, and 12-ft. cable pack); typical specifications: 10% relative efficiency, 1.75 keV resolution at 1.332 MeV, 41:1 peak-to-Compton ratio. • 659 0–5 keV Detector Bias Supply • 672 Spectroscopy Amplifier • 480 Pulser • C-24-12 Cables (2 ea.) • C-24-1 Cable • C-29 BNC Tee Connector • 4001A/4002D NIM Bin and Power Supply • TRUMP-PCI-8K Plug-In MCA Card (other ORTEC MCAs may be used)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Water radiolysis by gamma –irradiation for high quality synthesis of Nickel Oxide nano sheet

A simple, time effective and cost effective, methos was reported for synthesis of nickel oxide nanostructure. The NiO nanostructure was synthesized by gamma-irradiation method from NiSO4 precursor. The solution was irradiated by 60Co gamma-ray source at the dose rate of 40 Gy/min for determined time. The synthesized powders are characterized by means of X-ray powder diffraction (XRD), Energy-di...

متن کامل

The Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

متن کامل

Gamma-Ray Spectroscopy of Nuclei Along the Z=115 Decay Chain

During the past decade correlated α-decay chains have been observed in several independent experiments using Ca-induced fusion-evaporation reactions on actinide targets [1]. These are interpreted to originate from the production of isotopes with proton numbers Z = 113-118. In a recent experiment at the GSI Helmholtzzentrum für Schwerionenforschung GmbH in Darmstadt, Germany, using the reaction ...

متن کامل

Comparisons of the DSPEC and DSPEC Plus Spectrometer Systems

A previous experimental evaluation’ of nine commercial gamma-ray spectroscopy systems demonstrated significant benefits of digital signal processing for improvements in the performance of high-resolution gamma-ray spectroscopy systems. Spectacular improvements in the energy resolution and throughput of germanium detectors were demonstrated for the DSPEC. Recently, a new, improved version of DSP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006