Rapid compressions in a captive bubble apparatus are isothermal.

نویسندگان

  • Wenfei Yan
  • Stephen B Hall
چکیده

Captive bubbles are commonly used to determine how interfacial films of pulmonary surfactant respond to changes in surface area, achieved by varying hydrostatic pressure. Although assumed to be isothermal, the gas phase temperature (Tg) would increase by >100 degrees C during compression from 1 to 3 atm if the process were adiabatic. To determine the actual change in temperature, we monitored pressure (P) and volume (V) during compressions lasting <1 s for bubbles with and without interfacial films and used P x V to evaluate Tg. P x V fell during and after the rapid compressions, consistent with reductions in n, the moles of gas phase molecules, because of increasing solubility in the subphase at higher P. As expected for a process with first-order kinetics, during 1 h after the rapid compression P x V decreased along a simple exponential curve. The temporal variation of n moles of gas was determined from P x V >10 min after the compression when the two phases should be isothermal. Back extrapolation of n then allowed calculation of Tg from P x V immediately after the compression. Our results indicate that for bubbles with or without interfacial films compressed to >3 atm within 1 s, the change in Tg is <2 degrees C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study of Bubble Separation and Motion Using Lattice Boltzmann Method

In present paper acombination of three-dimensional isothermal and two-dimensional non-isothermal Lattice Boltzmann Method have been used to simulate the motion of bubble and effect of wetting properties of the surface on bubble separation. By combining these models, three-dimensional model has been used in two-dimension for decreasing the computational cost. Firstly, it has been ensured that th...

متن کامل

Mechanism and Prevention of Scale Formation in Boilers

Nucleate boiling heat transfer coefficients may be strongly reduced by scale formation, even for conditions where the bulk foulant concentration is well below the saturation concentration. Due to the mechanism of micro-layer evaporation, the local concentration at the heat transfer surface can be considerably increased, causing the formation of scale and changes in bubble frequency and bubble d...

متن کامل

Further development of Axisymmetric Drop Shape Analysis-captive bubble for pulmonary surfactant related studies.

The methodology combining Axisymmetric Drop Shape Analysis (ADSA) with a captive bubble (ADSA-CB) facilitates pulmonary surfactant related studies. The accuracy of ADSA-CB is crucially dependent on the quality of the bubble profile extracted from the raw image. In a previous paper, an image analysis scheme featuring a Canny edge detector and a Axisymmetric Liquid Fluid Interfaces-Smoothing (ALF...

متن کامل

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

Rapid evaporation at the superheat limit

In an experimental investigation of the transient processes that occur when a single droplet of butane at the superheat limit vaporizes explosively, short-exposure photographs and fast-response pressure measurements have been used to construct a description of the complete explosion process. It is observed that only a single bubble forms within the drop during each explosion, and that the growt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 95 5  شماره 

صفحات  -

تاریخ انتشار 2003