Treatment of complex proximal tibia fractures with the less invasive skeletal stabilization system.
نویسندگان
چکیده
OBJECTIVE Proximal tibia fractures with metaphyseal comminution present a difficult treatment challenge. The Less Invasive Skeletal Stabilization (LISS) internal fixator system has theoretical advantages (minimally invasive fixed angle construct) for the treatment of these injuries. This report presents clinical results of the LISS system for treatment of complex proximal tibia fractures and illustrates the unique properties of the system. DESIGN Prospective clinical trial. SETTING Level I trauma center. PATIENTS Twenty-eight consecutive patients with comminuted proximal tibia metaphyseal fractures (41A3, 41C2, or 41C3) treated with LISS plates. OUTCOME MEASUREMENTS Healing, fracture alignment, infectious and implant-related complications, and functional outcome based on the Lower Extremity Measure (LEM). RESULTS Average follow-up was 23 months (range 12-48). Thirty-seven of 38 patients healed their fracture after the index procedure. The other healed after implant removal without the need for further fracture repair. Postoperative fracture alignment was satisfactory in 37 of the 38 cases and was maintained in all patients at union. There were no infectious complications. The average LEM score was 88. CONCLUSIONS The LISS internal fixator system can be used successfully to treat complex proximal tibia fractures without the need for additional medial stabilization. Surgeons attempting to use fixed angle internal fixation plating systems should familiarize themselves with the significant technical differences between these and traditional plating systems to assure satisfactory results.
منابع مشابه
Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures.
OBJECTIVE To summarize the surgical experience and clinical results of the first 89 fractures of the proximal tibia treated with the Less Invasive Stabilization System (LISS; Synthes, Paoli, PA). DESIGN Retrospective analysis of prospectively enrolled patients into a database. SETTING Academic level I trauma center. SUBJECTS/PARTICIPANTS Eighty-seven consecutive patients with 89 proximal ...
متن کاملReverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases
BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors s...
متن کاملInsufficiency fracture of the proximal fibula and then tibia: a case report.
Elderly people with osteoarthritis of the knee and postpartum women are at risk of insufficiency fractures of the proximal fibular or tibia. We report on an 82-year-old woman with valgus osteoarthritis of the knee who developed insufficiency fractures of the right proximal fibula and then the right proximal tibia. She underwent total knee arthroplasty using a long tibial stem and a tibial locki...
متن کاملExternal Fixation Using Femoral Less Invasive Stabilization System Plate in Tibial Proximal Metaphyseal Fracture
BACKGROUND The locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed fractures. The purpose of this study is to evaluate the results of external fixation using the femoral less invasive stabilization system (LISS) plate in proximal metaphyseal fractures of the tibia. MET...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 18 8 شماره
صفحات -
تاریخ انتشار 2004