Intraocular lens tilt and decentration: a concern for contemporary IOL designs.

نویسنده

  • J B Ale
چکیده

PURPOSE To review published studies reporting the posterior chamber intraocular lens tilt and decentration after surgically uneventful implantation. Potential influences of normally occurring misalignment of modern designs of IOL on the optical performances are discussed. MATERIALS AND METHODS Published theoretical and clinical studies in relation to primarily implanted posterior chamber intraocular lenses and reports relating to more recent development of intraocular lens technologies were reviewed. RESULTS Capsulotomy type and integrity, ocular pathology, fixation position of the haptics are some of the important factors causing the misalignment. On an average, a 2-3 degrees tilt and a 0.2 -0.3 mm decentration are common, and which remain clinically unnoticed for any design of IOL. However, theoretical studies predict deterioration of retinal image quality particularly with customized wavefront correcting IOLs. More than a 10 degrees tilt and above 1 mm decentration are occasionally reported even with modern cataract surgery in about 10 % of pseudophakic population. CONCLUSIONS The rate and extent of the complication have lowered substantially concomitant with developments in surgical techniques and IOL designs. While emerging designs of modern IOLs offer improved quality of postoperative vision, optimum performance is vastly influenced by the position of the device in the eye. Therefore, additional precision in alignment of modern designs of IOL may be warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular lens alignment from purkinje and Scheimpflug imaging.

The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system ...

متن کامل

Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting

The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the ante...

متن کامل

Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation.

AIM To prospectively investigate changes in the area of the anterior capsule opening, and intraocular lens (IOL) decentration and tilt after implantation of a hydrogel IOL. METHODS 100 patients underwent implantation of a hydrogel IOL in one eye and an acrylic IOL implantation in the opposite eye. The area of the anterior capsule opening, and the degree of IOL decentration and tilt were measu...

متن کامل

Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...

متن کامل

Intraocular lens tilt and decentration measurements: Purkinje imaging versus Scheimpflug imaging

Purpose: To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems. Methods: Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus) and custom algorithms, and a custom-built Purkinje imaging apparatus. Both methods were validated with a physical model eye where tilt and decentration can b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2011