Urine pH: the effects of time and temperature after collection.
نویسندگان
چکیده
The Mandatory Guidelines for Federal Workplace Drug Testing Programs provide criteria for specimen validity testing, including urine pH cut-offs, to report a urine specimen as adulterated or invalid. Since the urine pH criteria for invalid classifications, > or = 3 and < 4.5 or > or = 9 and < 11, became effective in November 2004, a number of specimens with results within the upper invalid limits, typically in the range of 9.1 to 9.3, have been reported with no evidence of adulteration. This study evaluated the hypothesis that these pH findings were the result of exposure to increased environmental temperatures during specimen standing and transport. Indeed, increased storage temperatures were associated with increased urine pH, with the magnitude of the change related to both storage time and temperature. The pH values of specimens stored at -20 degrees C are relatively stable, whereas pH results > 9 are achieved at storage temperatures of room temperature or higher. It is noteworthy that no condition(s) produced a specimen with a pH > 9.5. Degradation of nitrogenous urine analytes is most likely responsible for the noted increases in pH. These findings are intended to supplement information used by the Medical Review Officers who are responsible for interpreting such marginally invalid pH results.
منابع مشابه
Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...
متن کاملDetermination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...
متن کاملFeasibility evaluation of trace amount of zinc in urine samples using atomic absorption solidified floating organic drop micro-extraction technique
Background: The present study was carried out with the aim of extracting trace amounts of zinc in urine samples with ultrasound-assisted emulsification solidified floating organic drop micro-extraction (USAE-SFODME) method by flame atomic absorption spectrometry (FAAS). The efficiency was investigated using the solvent extraction volume, extraction pH, time sonication and temperature extraction...
متن کاملApplication of response surface methodology to optimize the ultraviolet/hydrogen peroxide process for the removal of Reactive Red 195 dye from aqueous solution
Background and Objective: The most used dyes in textile industries are Azo Group dyes. Azo dyes have complex aromatic compounds, low chemical and biodegradable stability. Due to these properties, treatment of this type of wastewater by conventional methods will not meet environmental standards. The advanced oxidation process has been widely used to treat organic matter from wastewater. In this ...
متن کاملمقایســه اندازهگیری سطح آلبومین به روش ایمونوتوربیدومتری در ســه شیوه مختلف نـمونهگیری ادراری برای غربالگری آلبومینوری در بیماران دیابتی
Background: Microalbominuria (MA) is early presentation of renal damage which acts as an independent factor of cardiovascular events in these patients. There are various methods for sampling and also different laboratory tests to measuring albominuria. The aim of this study was to compare of different urine collection methods for measuring albominuria using immunoturbidometry assay which has a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 31 8 شماره
صفحات -
تاریخ انتشار 2007