Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators

نویسندگان

  • Ashraf Hassouna
  • Yasir Abdulaziz Bahadur
  • Camelia Constantinescu
چکیده

PURPOSE To retrospectively assess the incidence and magnitude of air pockets around vaginal cylinders and its impact on dose distribution in vaginal cuff image-guided high-dose-rate (HDR) brachytherapy. MATERIAL AND METHODS Fifty endometrial carcinoma patients treated by postoperative HDR vaginal cuff brachytherapy were included in the study. The average age of patients was 58.3 ± 11.8 years (range: 31-87 years). Brachytherapy was performed using cylindrical applicators, and the dose prescribed to 0.5 cm from the applicator's surface, over a length of 5 cm from the applicator's tip. Computed tomography (CT) simulation was used for each brachytherapy fraction. The incidence, vaginal mucosa displacement, volume, and dosimetric effect of air pockets around the vaginal cylinder were evaluated. RESULTS A total of 78 air pockets were found in 29/50 patients (58%) and 45/135 (33%) brachytherapy plans. They were located at the apex: 16/78 (20%) and lateral to the applicator: 62/78 (80%). The volume of air pockets ranged between 0.01 and 2.1 cm(3) (mean: 0.15 cm(3) ± 0.36 cm(3)), and the maximum displacement of vaginal mucosa from cylinder surface was between 0.1 and 1.09 cm (mean: 0.34 cm ± 0.2 cm). The dose reduction to the vaginal mucosa generated by the air pockets ranged from 0.5 to 66% (mean: 26.4% ± 13.9%). CONCLUSIONS The presence of air pockets around vaginal cylinder applicators is frequently noticed in post-operative vaginal cuff brachytherapy. The dose to the vaginal mucosa is reduced, as a result of displacement generated by air pockets. The effect on the clinical outcome of this dose reduction is yet to be determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology

PURPOSE Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS Three brachytherapy patients with unique clinical needs were identified as likely to benefit from a customized vaginal applicator. Pat...

متن کامل

Pii: S1538-4721(02)00051-x

Purpose: To investigate the dosimetric differences between colpostats and cylinder applicators for intravaginal brachytherapy. Methods and Materials: Dose distributions near vaginal colpostats and dome cylinders were computed with a commercial high–dose-rate treatment-planning system and verified by spot measurements by using LiF thermoluminescent dosimeters. Taking source anisotropy into a...

متن کامل

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...