Automatic detection of device setup errors in radiotherapy by matching three-dimensional CT data and portal images

نویسندگان

  • R. Tschirley
  • J. Beier
  • P. Wust
چکیده

In order to achive best results in radiotherapeutic treatment of tumor tissue, one needs to precisely reconstruct the setup defined in therapy planning before the treatment can start. Inaccuracies in either defining the treatment parameters or transferring positioning markers to the patient’s body, errors in treatment device setup or patient motion during the treatment result in a displacement of the irradiated volume. If the dose applied to the clinical target volume (CTV) is reduced, the tumor may not be controlled as predicted and the risk of recidivists rises. In view of the different possible inaccuracies, a planning target volume (PTV) is defined which is larger than CTV and incorporates it. The major goal of the described project is to minimize the difference of PTV and CTV. In conventional radiotherapy, the patient’s setup is performed by using isocenter laser pointers and light projections of the treatment beam which have to match markers on the patient’s skin. Then, two or more portal images (PI) are generated to control the patient’s positon and to correct setup errors. To detect errors at least semi-automatically, artificial markers must be fastened to the patient or anatomical landmarks have to be selected. This paper discusses an approach where a computer detects and corrects errors at high precision without the need of manual interaction or use of artificial landmarks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

Image-guided prostate radiotherapy: analysis of inter- fractional setup errors

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

متن کامل

Towards Automatic, Model-Driven Determination of 3D Patient Setup Errors in Conformal Radiotherapy

The accurate and quantitative determination of three-dimensional patient setup errors in conformal radiotherapy, including setup errors due to out-of-plane rotations, requires methods for registering pre-treatment, three-dimensional planning CT images with intra-treatment, two-dimensional portal images. We have developed a method for performing such a registration based on structural models tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999