Auditory force feedback substitution improves surgical precision during simulated ophthalmic surgery.
نویسندگان
چکیده
PURPOSE To determine the extent that auditory force feedback (AFF) substitution improves performance during a simulated ophthalmic peeling procedure. METHODS A 25-gauge force-sensing microforceps was linked to two AFF modes. The "alarm" AFF mode sounded when the force reached 9 mN. The "warning" AFF mode made beeps with a frequency proportional to the generated force. Participants with different surgical experience levels were asked to peel a series of bandage strips off a platform as quickly as possible without exceeding 9 mN of force. In study arm A, participants peeled with alarm and warning AFF modes, the order randomized within the experience level. In study arm B, participants first peeled without AFF, then alarm or warning AFF (order randomized within the experience level), and finally without AFF. RESULTS Of the 28 "surgeon" participants, AFF improved membrane peeling performance, reducing average force generated (P < 0.01), SD of forces (P < 0.05), and force × time above 9 mN (P < 0.01). Short training periods with AFF improved subsequent peeling performance when AFF was turned off, with reductions in average force, SD of force, maximum force, time spent above 9 mN, and force × time above 9 mN (all P < 0.001). Except for maximum force, peeling with AFF reduced all force parameters (P < 0.05) more than peeling without AFF after completing a training session. CONCLUSIONS AFF enables the surgeon to reduce the forces generated with improved precision during phantom membrane peeling, regardless of surgical experience. New force-sensing surgical tools combined with AFF offer the potential to enhance surgical training and improve surgical performance.
منابع مشابه
Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery
Vitreoretinal surgeons use 0.5 mm diameter instruments to manipulate delicate tissue inside the eye while applying imperceptible forces that can cause damage to the retina. We present a system which robotically regulates user-applied forces to the tissue, to minimize the risk of retinal hemorrhage or tear during membrane peeling, a common task in vitreoretinal surgery. Our research platform is ...
متن کاملEffect of sensory substitution on suture manipulation forces for surgical teleoperation.
Bilateral telemanipulation, which applies haptic feedback to the operator, is not yet available in most commercial robot-assisted surgical systems. We have shown in previous work that the lack of haptic (force or tactile) feedback is detrimental in applications requiring fine suture manipulation. In this paper, we study the effect of substituting direct haptic feedback with visual and auditory ...
متن کاملRobotic Surgery in Gynecology
Minimally invasive surgery (MIS) can be considered as the greatest surgical innovation over the past 30 years. It revolutionized surgical practice with well-proven advantages over traditional open surgery: reduced surgical trauma and incision-related complications, such as surgical-site infections, postoperative pain and hernia, reduced hospital stay, and improved cosmetic outcome. Nonetheless,...
متن کاملHaptic Feedback in a Telepresence System for Endoscopic Heart Surgery
The implementation of telemanipulator systems for cardiac surgery enabled heart surgeons to perform delicate minimally invasive procedures with high precision under stereoscopic view. At present, commercially available systems do not provide force-feedback or Cartesian control for the operating surgeon. The lack of haptic feedback may cause damage to tissue and can cause breaks of suture materi...
متن کاملSensory subtraction via cutaneous feedback in robot-assisted surgery
This paper presents a novel approach to force feedback in robot-assisted surgery. Haptic stimuli, consisting of kinesthetic and cutaneous components, are substituted with cutaneous feedback only. This new approach to sensory substitution is called sensory subtraction, as it subtracts the destabilizing kinesthetic part of the haptic interaction to leave only cutaneous cues. In order to evaluate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 54 2 شماره
صفحات -
تاریخ انتشار 2013