Evaluation of gallbladder motility: comparison of two-dimensional and three-dimensional ultrasonography.
نویسندگان
چکیده
Since impaired gallbladder emptying contributes to gallstone formation, the evaluation of gallbladder motility requires accurate methodology. Recently developed 3-dimensional ultrasonography may take into account various gallbladder shapes more accurately than conventional 2-dimensional ultrasonography. Therefore, volumes of water-filled balloons of various sizes were determined in vitro by 2-dimensional ultrasonography with the sum of cylinders method and by 3-dimensional ultrasonography. Also, in 15 gallstone patients and 6 healthy volunteers, fasting gallbladder volumes and postprandial motility were determined by both methods. Volumes of water-filled balloons as measured by both methods correlated strongly with true volumes (R= 0.93 for 2-dimensional and R = 0.98 for 3- dimensional ultrasonography). Gallbladder volumes measured by both methods were also correlated (R = 0.66, P <0.001). In gallstone patients, 3-dimensional ultrasonography yielded smaller gallbladder volumes than 2-dimensional ultrasonography (P = 0.007), but not in healthy subjects. With both methods, gallstone patients exhibited decreased postprandial gallbladder motility compared to healthy subjects. In conclusion, gallbladder volume measurements by 3-dimensional and 2-dimensional ultrasonography are strongly correlated.Nevertheless, in gallstone patients, gallbladder volumes by 3-dimensional ultrasonography tend to be smaller than by 2-dimensional ultrasonography, possibly due to interference of gallstones with the volume measurement.
منابع مشابه
Three-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملThree-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs
Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...
متن کاملThree-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs
Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...
متن کاملThree-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog
Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of hepatology
دوره 6 3 شماره
صفحات -
تاریخ انتشار 2007