Feasibility of a bihormonal closed-loop system to control postexercise and postprandial glucose excursions.

نویسندگان

  • Arianne C Van Bon
  • Lisanne D Jonker
  • Rob Koebrugge
  • Robin Koops
  • Joost B L Hoekstra
  • J Hans DeVries
چکیده

BACKGROUND The aim of this pilot study was to test the feasibility of a bihormonal (glucagon and insulin) closed-loop (CL) system by challenging the system with two meals and 30 min exercise. METHODS Ten patients with type 1 diabetes treated with continuous subcutaneous insulin infusion underwent a standardized protocol on three different occasions: 40 g carbohydrate breakfast followed 2 h later by 30 min of moderate-intensity exercise, followed 1.5 h later by a standardized 60 g carbohydrate lunch. An open-loop (OL) day served as control, the first CL day as tuning experiment, and the second CL day to compare with OL. RESULTS The overall mean venous glucose was similar: 9 (5.4-13.5) mmol/liter in OL versus 8.7 (6.4-11.0) mmol/liter in CL, p = .74. The postbreakfast glucose concentrations tended to be lower in OL than in CL [9.5 (4.3-13.3) versus 11.4 (7-16.2) mmol/liter; p = .07] and higher in OL than in CL postlunch [9.4 (6.0-14.9) versus 7.7 (5.5-9.0) mmol/liter,p = .15]. The postexercise glucose concentrations were similar in OL and CL: 7.5 (4.6-13) versus 8.2 (5.5-13.1) mmol/liter; p = .45. In those patients coming in with baseline glucose above 7 mmol/liter, there was initial overinsulinization in CL. During OL, two hypoglycemic episodes occurred compared with four hypoglycemic episodes in three participants during CL. Glucagon seemed mostly effective in preventing hypoglycemia. CONCLUSIONS Overall, CL glucose control was comparable to OL control, but there was overinsulinization in those patients with baseline glucose above 7 mmol/liter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas.

OBJECTIVE The most promising beta-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characte...

متن کامل

A feasibility study of bihormonal closed-loop blood glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic swine.

BACKGROUND We sought to test the feasibility and efficacy of bihormonal closed-loop blood glucose (BG) control that utilizes subcutaneous (SC) infusion of insulin and glucagon, a model-predictive control algorithm for determining insulin dosing, and a proportional-derivative control algorithm for determining glucagon dosing. METHODS Thirteen closed-loop experiments (approximately 7-27 h in le...

متن کامل

Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience.

BACKGROUND Recent progress in the development of clinically accurate continuous glucose monitors (CGMs), automated continuous insulin infusion pumps, and control algorithms for calculating insulin doses from CGM data have enabled the development of prototypes of subcutaneous closed-loop systems for controlling blood glucose (BG) levels in type 1 diabetes. The use of a new personalized model pre...

متن کامل

Closed-Loop Control Performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System in a Feasibility Study.

BACKGROUND This feasibility study investigated the insulin-delivery characteristics of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System-an automated insulin delivery device-in participants with type 1 diabetes. METHODS Thirteen adults with type 1 diabetes were enrolled in this nonrandomized, uncontrolled, clinical-research-center-based feasibility study. The HHM System comprised a contin...

متن کامل

Effect of insulin feedback on closed-loop glucose control: a crossover study.

BACKGROUND Closed-loop (CL) insulin delivery systems utilizing proportional-integral-derivative (PID) controllers have demonstrated susceptibility to late postprandial hypoglycemia because of delays between insulin delivery and blood glucose (BG) response. An insulin feedback (IFB) modification to the PID algorithm has been introduced to mitigate this risk. We examined the effect of IFB on CL B...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2012