The use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows.
نویسندگان
چکیده
Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7). There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N. FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken.
منابع مشابه
Technique Using Isoelastic Tension Band for Treatment of Olecranon Fractures.
The isoelastic ultrahigh-molecular-weight polyethylene tension band may be considered an alternative to stainless steel wire for tension band fixation of olecranon fractures. In this article, we present our technique using this isoelastic tension band and describe the outcomes of 7 patients who underwent open reduction and internal fixation of closed, displaced olecranon fractures with minimal ...
متن کاملMedial malleolar fractures: a biomechanical study of fixation techniques.
Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...
متن کاملBraided Polyester Suture Fatigue Failure When Treating Transverse Patellar Fracture: A Case Report
The incidence of patellar fractures accounts for almost 1% of all skeletal fractures. In case of a displaced patellar fracture, surgical intervention is often advocated for earlier stability, restoration of knee motion, and shortened morbidity. Among various fixations, the AO modified tension band technique, which incorporates two parallel Kirschner wires with an anterior tension band, is the m...
متن کاملModified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1
Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25...
متن کاملFixation of extra articular fracture of inferior pole of patella by on needle stainless steel suture wire
The patella is the largest sesamoid bone in the body. As the patella bone is responsible for the strong extensor mechanism of the knee joint, its reconstruction and anatomical restoration after fracture is always desirable over excision. Extra articular fracture of lower pole of patella accounts for less than 10 percent of all patellar fractures. The treatment of these fractures is complicated,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 92 2 شماره
صفحات -
تاریخ انتشار 2010