Development and validation of a reversed-phase HPLC method for analysis of tetrahydrozoline hydrochloride in eye drop formulations
نویسندگان
چکیده
A simple, precise, accurate, and stability-indicating method is developed and validated for analysis of tetrahydrozoline hydrochloride in eye drop formulations. Separation was achieved on a reversed-phase C8 column (125 mm×4.6 mm i.d., 5 μm) using a mobile phase consisting of acetonitrile/phosphate buffer of pH 3.0 (20:80, v/v) at a flow rate of 1.0 mL/min and UV detection at 240 nm. This method is validated according to United States Pharmacopeia requirements for new methods, which include accuracy, precision, selectivity, robustness, and linearity and range. This method shows enough selectivity, accuracy, precision, and linearity and range to satisfy Federal Drug Administration/International Conference on Harmonization regulatory requirements. The current method demonstrates good linearity over the range of 0.025-0.075 mg/mL of tetrahydrozoline with r2 0.999. The average recovery of the method is 100.8% with a relative standard deviation of 0.47%. The degree of reproducibility of the results obtained as a result of small deliberate variations in the method parameters and by changing analytical operators has proven that the method is robust and rugged.
منابع مشابه
Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملSimultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کامل