Abstract: In this paper, we propose a new test method for detecting an open lead which occurs when an IC is mounted on a printed circuit board. In the method, an open lead is detected by observing output logical change of an open lead detector. Since the test method is a vectorless test one, test generation and test input application are not needed. Testability of the test method is examined by some experiments. The results show that open leads of SSIs and LSIs will be detected by the method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variable Speed Wind Turbine DFIG Back to Back Converters Open-Circuit Fault Diagnosis by Using of Combiniation Signal-Based and Model-Based Methodes

Condition monitoring (CM) and Fault Detection (FD) of wind turbine lead to increase in reliability and availability of turbine. IGBT open circuit of wind turbine converter will bring about depletion in output current of converter and as a result, reduction in production of wind turbine power. In this research, back to back converter IGBT open - gate fault for wind turbine based on DFIG is detec...

متن کامل

Test Circuit for Vectorless Open Lead Detection of CMOS ICs

In this paper, a test circuit for a test method is proposed, with which open leads of CMOS logic ICs are detected without generating test input vectors. Open leads are detected by means of supply current of the test circuit that flows when an AC voltage signal is provided to targeted leads with test probes as a stimulus. It is examined by some experiments whether open leads will be detected wit...

متن کامل

Alleviating the Small-Signal Oscillations of the SMIB Power System with the TLBO–FPSS and SSSC Robust Controller

Power systems are subjected to small–signal oscillations that can be caused by sudden change in the value of large loads. To avoid the dangers of these oscillations, the Power System Stabilizers (PSSs) are used. When the PSSs can not be effective enough, installation of the Thyristor–based compensators to increase the oscillations damping is a suitable method. In this paper, a Static Synchronou...

متن کامل

A New Simple Single Phase AC-AC Switching Voltage Regulator Cum Power Conditioner

A new very simple single phase ac-ac voltage regulator based on LC network is proposed here that compensates wide range supply voltage variations. This has the capability of both buck and boost the input source voltage level without any change of phase angle. The number of components used in the converter circuit is minimum and smooth output waveform can be achieved without any additional filte...

متن کامل

Implementation of ROCOPS Method for Anti-Islanding Protection of Wind Turbine

In recent years, based on the growing importance of clean energy in comparison with conventional energy production from fossil fuels, DG systems are gradually becoming more popular all over the world. These resources solve many problem of system. However, these resources create some other problems too. One of the most problem of DGs is unwanted islanding. This paper addresses reliable passive i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008