Voltage Unbalance Problems and Solutions for Electrified Railway Systems

نویسندگان

  • Farhad Shahnia
  • Rasoul Esmaeilzadeh
چکیده

Voltage and current unbalance problems of power networks due to AC electrified railway systems are studied and their influences such as the voltage unbalance factor and the current negative sequence contribution factor injected to the network are calculated. Several methods can be used for reducing the power quality unbalance problems which have been proposed and the best of them is chosen by comparing the results of their unbalance and current negative sequence contribution factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Induction Motor Characteristics and Applications for Dc Electrified Railway Systems

Induction motor structures in DC electrified railways with their dynamic performance are studied. Characteristics of the current, voltage, electrical and mechanical torque and active and reactive power in accelerating, normal and regenerative braking are investigated. The characteristics of the induction motors used for Tabriz urban railway are simulated with PSCAD/EMTDC software proving the in...

متن کامل

Research of Electrified Railway Harmonic Suppression Based on H-infinity Control

Because of using the nonlinear high-power, single-phase, multi-step full wave or bridge rectifier electric locomotive in electrified railway, the electrified railway traction power supply system has serious power quality problems, which affect safe operation of the electrified railway and impact the local power grid adversely. Aiming at the electrified railway power quality problems, a homogeni...

متن کامل

A Comparison Between Electrical Circuit and Finite Element Modeling Methods for Performance Analysis of a Three-Phase Induction Motor under Voltage Unbalance

Induction motor is the most popular load in the industry, it is very important to study about the effects of voltage quality on induction motor performance. One of the most important voltage quality problems in power system is voltage unbalance. This paper evaluates and compares two methods including finite element method (FEM) and equivalent electrical circuit simulation for investigation ...

متن کامل

A Direct Power Feeding System for AC Railway Networks Using Modular Multilevel Converter

Abstract Traditional railway power supply systems impose substantial power quality problems (PQ) on the utility network, such as unbalance, harmonics and a large amount of reactive power. This paper proposes a topology based on three-phase to single-phase modular multilevel converters (MMC) to obviate these problems. The MMC based traction substations (TSS) are connected directly to the utili...

متن کامل

Multi-conductor transmission line model for electrified railways: A method for including responses of lumped devices

For studying the response to transients caused by lightning and other electromagnetic disturbance sources, electrified railway systems can be represented as a system of multiconductor transmission lines (MTL) above a finitely conducting ground. The conductors present in this system would be wires for traction power supply, auxiliary power, return conductors for traction current, the tracks, and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005