SU-E-J-138: Fast 2-D Fiducial Marker Detection on Sequential MV Projections in Arc Therapy.

نویسندگان

  • H Van Herck
  • W Crijns
  • P Slagmolen
  • F Maes
  • F Van den Heuvel
  • K Haustermans
چکیده

PURPOSE To automatically detect intrafraction motion during arc radiotherapy for prostate cancer patients by tracking fiducial markers in two-dimensional MV images acquired using the treatment beam, in order to adjust radiation dose accordingly. METHODS Four fiducial gold markers are implanted in a patient's prostate. Patients are irradiated using a Varian Linac 2100 C/D with RapidArc upgrade (Varian Medical Systems, Palo Alto, CA). MV images (1024 × 768 pixels, 0.392 × 0.392 mm2 pixel size) acquired during a 360 degree gantry rotation at a one second interval (5 degrees) are preprocessed by subtracting a smoothed version of the image to retain only high image frequencies. Edge detection is then applied, followed by a one pixel wide dilation and erosion to transform the edges into contiguous regions. Next, our method searches the centers of visible markers (i.e. not covered by the MLC), constrained by marker estimates from the planning CT. This is done by finding all contiguous regions and maximizing a marker-region distance criterion for every visible marker. A two-dimensional estimate correction over consecutive projections is also implemented to improve marker estimates during gantry rotation. RESULTS We applied our method on four treatment fractions of the same patient. As such, a total of 191 projections with manually indicated marker ends as ground truth were used as validation. Markers were indicated twice on all images, to include observer errors. Results show a mean detection error of less than 0.5 mm in the projection image (standard deviation 0.6 mm), with an execution time of less than one second per image in matlab. Undetected markers and false positives mostly occurred at moving leaf boundaries, where marker visibility was determined by the observer. CONCLUSIONS Preliminary findings demonstrate that this method can be used to detect intrafraction motion during arc radiotherapy by only using projected MV images. Research sponsored by Varian Medical Systems, Palo Alto, CA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy.

PURPOSE Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. METHODS The expec...

متن کامل

WE-G-213CD-05: Beam's-Eye-View Prostate Motion Detection during Arc Radiotherapy.

PURPOSE To track prostate motion during clinical arc radiotherapy using a novel statistical motion tracking algorithm in both phantom and patient systems. METHODS For the phantom study, a dynamic phantom with a custom tumor model and radiopaque fiducials was used. For the patient study, the clinical data from two prostate patients were acquired during volumetric modulated arc therapy (VMAT). ...

متن کامل

TU-E-BRA-04: Real-Time Automatic Fiducial Marker Detection in Low Contrast Cine-MV Images.

PURPOSE Intrafraction motion tracking using beam-line MV images have gained much attention because no additional imaging dose is introduced. Since MV images have much lower contrast than kV images, a robust marker detection algorithm is a pre-requisite. In this work, we develop a novel, fast, and robust method to detect implanted markers in low-contrast cine-MV patient images. METHODS Several...

متن کامل

Fast line, arc/circle and leg detection from laser scan data in a Player

A feature detection system has been developed for real-time identification of lines, circles and legs from laser data. A new method suitable for arc/circle detection is proposed: the Internal Angle Variance (IAV). Lines are detected using a recursive line fitting method. The people leg detection is based on geometrical constrains. The system was implemented as a fiducial driver in Player, a mob...

متن کامل

First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.

PURPOSE For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. METHODS AND MATERIALS The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millenniu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part8  شماره 

صفحات  -

تاریخ انتشار 2012