BACKGROUND Reservation of blood leads to blood wastage if the blood is not transfused. Therefore, in some centers only blood type and screen are evaluated. In this study, the efficacy of a blood crossmatch-to-transfusion ratio was measured and then compared with the standard levels. METHODS This prospective study was conducted during one year in a university hospital. During this period, 398 patients for whom blood had been requested were studied. In these patients, at the first surgical type, the laboratory tests (hematocrit, hemoglobin, platelet count, and prothrombin time) and the number of preoperative crossmatched and intraoperative transfused blood units were recorded. Then the crossmatch-to-transfusion ratio, transfusion probability, transfusion index, and correlation between related factors, and the transfusion ratio were evaluated. RESULTS In this cross-sectional study, blood was requested for 398 patients. According to available blood unit deficiency, from 961 blood unit requisitions, only 456 units were crossmatched and 123 units were transfused. The crossmatch-to-transfusion ratio, transfusion probability, and transfusion index were 3.71 (7.81 if all requisitions were crossmatched), 16.83%, and 0.31, respectively. The most unfavorable indexes were observed in patients who had ear, nose, and throat surgeries (0 transfused from 19 crossmatched blood units) and obstetric and gynecologic surgery (crossmatch-to-transfusion ratio was 18.6). The best indexes were related to thoracic surgery and neurosurgery (crossmatch-to-transfusion ratio was 1.53 and 1.54, respectively). There were no significant correlations between hemoglobin, hematocrit, platelet count, and prothrombin time with the number of transfused blood units (P = 0.2, 0.14, 0.26, and 0.06, respectively). CONCLUSION The data for the crossmatch-to-transfusion ratio, transfusion probability, and transfusion index were suboptimal at this center, especially for ear, nose, and throat and obstetric and gynecologic surgeries. Further multidimensional studies and determination of a new model for blood requests and to decrease blood wastage are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Survey of Blood Request Versus Blood Utilization at a University Hospital in Iran

  Background: Reservation of blood leads to blood wastage if the blood is not transfused. Therefore, in some centers only blood type and screen are evaluated. In this study, the efficacy of a blood crossmatch-to-transfusion ratio was measured and then compared with the standard levels. Methods: This prospective study was conducted during one year in a university hospital. During this period, 39...

متن کامل

A Survey on Transfusion Status in Orthopedic Surgery at a Trauma Center

  Background: Increased costs and mortality associated with inappropriate blood transfusions have led to investigations about blood request and blood transfusion techniques. We investigated the transfusion status in patients who underwent orthopedic surgery in Poursina Hospital (Rasht, Iran) to optimizing blood usage and determine if a scheduled transfusion program for every orthopedic surgery ...

متن کامل

Maximum surgical blood ordering schedule improves blood utilization in elective surgeries :An experience in Faghihi hospital, Shiraz, Iran

Abstract Background and Objectives Over-ordering of blood before operation can cause unnecessary cross matches, blood bank staff overload, blood unit wastages due to outdating, and increase hospital costs. So, we aimed to survey the efficacy of MSBOS on blood utilization in Faghihi Hospital, Shiraz, Iran.   Materials and Methods This cross sectional study was conducted over a three month per...

متن کامل

A Collaborative Blood Distribution System in a Network of Hospitals based on their Normal and Emergency Requests: a Mathematical Model and Solution

Background and Objectives: A blood distribution network orchestrates distribution of safe blood products to hospitals. Blood shortage and blood wastage are two important factors which may affect efficiency of blood distribution network. Service delivery time is another factor that refers to the time interval between blood request by a hospital and transfusing it to the patient....

متن کامل

مقاله کوتاه: بررسی وضعیت مصرف خون در بیمارستان آموزشی ولی‌عصر (عج) بیرجند

Background and Aim: Efficiency of blood request and transfusion, if purposeful, can prevent wasting of blood in hospital wards and as a result, decrease overload on the blood bank and spare various expenses..The aim of the present descriptive study was to assess the efficiency of blood utilization in Vali-Asr educational hospital in Birjand in order to take an effective step to make medical cen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The archives of bone and joint surgery

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2016