BACKGROUND Implant malposition can produce unsatisfactory aesthetic results after breast augmentation. The goal of this article is to identify aspects of the preoperative surgical planning and intraoperative flap fixation that can prevent implant malposition. METHODS This study examined 36 patients who underwent primary dual plane breast augmentation through an inframammary incision between September 1, 2012 and January 31, 2013. Before the surgery, preoperative evaluation and design using the Randquist formula were performed. Each patient was evaluated retrospectively for nipple position relative to the breast implant and breast contour, using standardized preoperative and postoperative photographs. The average follow-up period was 10 months. RESULTS Seven of 72 breasts were identified as having implant malposition. These malpositions were divided into two groups. In relation to the new breast mound, six breasts had an inferiorly positioned and one breast had a superiorly positioned nipple-areolar complex. Two of these seven breasts were accompanied with an unsatisfactory breast contour. CONCLUSIONS We identified two main causes of implant malposition after inframammary augmentation mammaplasty. One cause was an incorrect preoperatively designed nipple to inframammary fold (N-IMF) distance. The breast skin and parenchyma quality, such as an extremely tight envelope, should be considered. If an extremely tight envelope is found, the preoperatively designed new N-IMF distance should be increased. The other main cause of malposition is failure of the fascial suture from Scarpa's fascia to the perichondrium through an inframammary incision. As well, when this fixation is performed, it should be performed directly downward to the perichondrium, rather than slanted in a cranial or caudal direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aesthetic Surgery Journal Shoelace Breast Cast on Behalf Of: American Society for Aesthetic Plastic Surgery

Implant malposition after breast augmentation surgery remains a common complication. Several surgical options exist to correct the resultant deformity; however, all involve additional risks, costs, and the increased potential for patient dissatisfaction. In my practice, I have developed a nonsurgical therapy using shoelaces, which, when tied and placed in a certain fashion, can correct this def...

متن کامل

Nipple-areola complex sensitivity after primary breast augmentation: a comparison of periareolar and inframammary incision approaches.

BACKGROUND The body of literature documenting normative breast sensation and postoperative changes in sensation after reduction mammaplasty has grown considerably over the last several years. Despite this, only two studies have ever been published on the subject of postaugmentation mammaplasty sensory outcomes. The purpose of this study was to precisely measure sensory thresholds at the nipple-...

متن کامل

The Inframammary Fold (IMF) Fixation Suture: Proactive Control of the IMF in Primary Breast Augmentation.

Previous reports have suggested that inferior implant malposition following primary breast augmentation is secondary to violation of the inframammary fold (IMF) and subsequent poor reconstitution of the scaffold during the initial surgical procedure. Additionally, inferior malposition may be related to occult weakness at the level of the IMF incision over time. Specifically, in an inframammary ...

متن کامل

BREAST Nipple-Areola Complex Sensitivity after Primary Breast Augmentation: A Comparison of Periareolar and Inframammary Incision Approaches

La Jolla, Calif., Baltimore, Md.; and Washington, D.C. Background: The body of literature documenting normative breast sensation and postoperative changes in sensation after reduction mammaplasty has grown considerably over the last several years. Despite this, only two studies have ever been published on the subject of postaugmentation mammaplasty sensory outcomes. The purpose of this study wa...

متن کامل

Endoscopic Correction of Inferior Implant Malposition in Augmented Breasts with Electrocauterization

Breast augmentation surgery has been the most popular cosmetic surgery in the United States since 2006, accounting for 290,000 cases in 2013 [1]. Unfortunately, complications from the procedure can result in a reoperation rate approaching 15.5%. Complications after breast augmentation include capsular contracture, size change, malposition, waviness, deflation, infection, ruptured gel, palpabili...

متن کامل