Simultaneous determination of trace rare-earth elements in simulated water samples using ICP-OES with TODGA extraction/back-extraction

نویسندگان

  • FuKai Li
  • AiJun Gong
  • LiNa Qiu
  • WeiWei Zhang
  • JingRui Li
  • Yu Liu
  • YuNing Liu
  • HuiTing Yuan
چکیده

The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N', N'-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous determination of 16 trace REEs in simulated water samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). With this method, TODGA was used as the extractant to perform the liquid-liquid extraction (LLE) sample pretreatment procedure. All 16 REEs were extracted from a 3 M nitric acid medium into an organic phase by a 0.025 M TODGA petroleum ether solution. A 0.03 M ethylenediaminetetraacetic acid disodium salt (EDTA) solution was used for back-extraction to strip the REEs from the organic phase into the aqueous phase. The aqueous phase was concentrated using a vacuum rotary evaporator and the concentration of the 16 REEs was detected by ICP-OES. Under the optimum experimental conditions, the limits of detection (3σ, n = 7) for the REEs ranged from 0.0405 ng mL-1 (Nd) to 0.5038 ng mL-1 (Ho). The relative standard deviations (c = 100 ng mL-1, n = 7) were from 0.5% (Eu) to 4.0% (Tm) with a linear range of 4-1000 ng mL-1 (R2 > 0.999). The recoveries of 16 REEs ranged from 95% to 106%. The LLE-ICP-OES method established in this study has the advantages of simple operation, low detection limits, fast analysis speed and the ability to simultaneously determine 16 REEs, thereby acting as a viable alternative for the simultaneous detection of trace amounts of REEs in water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zr and U determination at trace level in simulated deep groundwater by Q ICP-MS using extraction chromatography.

In the framework of trace element analysis by Q ICP-MS in a simulated deep Callovo-Oxfordian groundwater, separation procedures based on extraction chromatography were developed to eliminate the high salt contents and to concentrate Zr and U simultaneously. Theoretical and experimental speciation studies showed the importance of adjusting the medium to HNO₃/HF (0.5 M/0.005 M) to guarantee the s...

متن کامل

Synthesis and application of a novel magnetic nanocomposite for determination of trace Cd(II) in water samples

In this work for the first time, Fe3O4@SiO2 core-shell nanoparticles functionalized with isatin groups as a magnetic nanosorbent was applied for the simultaneous extraction of trace amounts of cadmium (II). The characterization of this nanosorbentwas studied using Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and X-ray diffraction (XRD). The effect of seve...

متن کامل

Determination of rare earth elements in geological samples by inductively coupled plasma atomic emission spectrometry with flow injection liquid-liquid extraction.

A direct sampling with organic solvent extracts for simultaneous multi-element determination implemented with inductively coupled plasma atomic emission spectrometry (ICP-AES) associated with a flow injection liquid-liquid extraction (FI-LLE) sample preconcentration method was studied. The "robustness" of the plasma discharge with tributyl phosphate (TBP) loading was diagnosed by using the Mg I...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Preconcentration and Determination of Trace Amounts of Aromatic Compounds in Non-alcoholic Beer Samples by In-syringe Dispersive liquid–liquid Microextraction

In this paper, a new simple and effective method based on dispersive liquid–liquid microextraction procedure is proposed for rapid and simultaneous separation and preconcentration of ultra trace amounts of benzene, toluene, ethyl benzene and xylenes (BTEX) in non-alcoholic Beer samples. In this experiment, a glass syringe was used as extraction unit. With this simple configuration, the centrifu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017