Interobserver agreement of EUS elastography in the evaluation of solid pancreatic lesions

نویسندگان

  • João-Bruno Soares
  • Julio Iglesias-Garcia
  • Bruno Gonçalves
  • Björn Lindkvist
  • Jose Lariño-Noia
  • Pedro Bastos
  • Ana Célia Caetano
  • Aníbal Ferreira
  • Pedro Pimentel-Nunes
  • Luís Lopes
  • Pedro Moutinho-Ribeiro
  • J. Enrique Dominguez-Muñoz
چکیده

BACKGROUND AND OBJECTIVES Previous reports assessing the reproducibility of endoscopic ultrasound elastography (EUS-E) in evaluation of solid pancreatic lesions (SPL) involved only experienced endosonographers. We aimed to assess the interobserver agreement (IOA) of EUS-E in the evaluation of SPL by endoscopists with different levels of experience in EUS and EUS-E. MATERIALS AND METHODS A cross-sectional observational multicenter study was designed and included 11 endoscopists who were divided into four groups: Group A (long experience in EUS and EUS-E); Group B (short experience in EUS and EUS-E); Group C (long experience in EUS and no experience in EUS-E); and Group D (no experience in EUS or EUS-E). The observers independently classified the patterns of 60 video sequences of EUS-E, after a 20-min training session. For each group, we calculated IOA (kappa statistic, k) of EUS-E and the diagnostic accuracy of EUS-E for pancreatic malignancy, by comparing the pattern of EUS-E indicative of malignancy (heterogeneous or homogenous blue) with the final diagnosis. RESULTS The overall IOA was moderate (k = 0.42; 95% confidence interval (CI) 0.33-0.52). The IOA of Group A (k = 0.80; 95% CI 0.65-1.00) was significantly higher than that of Groups B (k = 0.54; 95%CI 0.40-0.71), C (k = 0.54; 95%CI 0.39-0.68), and D (k = 0.28; 95%CI 0.14-0.40). IOA of Groups B and C was not significantly different, but it was significantly higher than that of Group D. The diagnostic accuracy of Group A (area under the curve under summary receiver operating characteristic (AUROC) = 0.83; 95%CI 0.75-0.90) was not significantly different from that of Group B (AUROC = 0.77; 95%CI 0.71-0.83), but it was significantly higher than that of Groups C (AUROC = 0.74; 95%CI 0.67-0.81) and D (AUROC = 0.74; 95%CI 0.67-0.81). No significant difference was seen between Groups B, C, and D for diagnostic accuracy. CONCLUSION EUS-E is reproducible in the evaluation of SPL, even between endoscopists with no or limited experience in EUS and/or EUS-E. Reproducibility and diagnostic accuracy increase with experience in EUS and EUS-E.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic Ultrasound Elastography for Pancreatic Cancer Diagnosis: A Step Forward?

(EUS) is not only useful for providing excellent images for detection and staging of pancreatic cancer; it also provides guidance for fine needle aspiration (FNA) and biopsies detected during a standard procedure. Overall accuracy of EUS-FNA can be considered excellent, with sensitivities between 80% and 85%, and specificities close to 100%. However, differentiation between pancreatic cancer an...

متن کامل

Interobserver agreement among cytopathologists in the evaluation of pancreatic endoscopic ultrasound-guided fine needle aspiration cytology specimens*

BACKGROUND AND AIMS Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has become the standard of care in the evaluation of solid pancreatic lesions. Limited data exist on interobserver agreement (IOA) among cytopathologists in assessing solid pancreatic EUS-FNA specimens. This study aimed to evaluate IOA among cytopathologists in assessing EUS-FNA cytology specimens of solid pancreati...

متن کامل

Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study.

AIM To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. METHODS A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph node (n = 101). The classification as benign or malignant, based on the real time elastography pa...

متن کامل

Endoscopic ultrasound in solid pancreatic masses--current state and review of the literature.

Some 25 years ago endoscopic ultrasound (EUS) was introduced in clinical practice for better visualization of pancreas. At the time of introduction EUS was superior to other methods in detection of pancreatic masses allowing tissue diagnosis by later introduced EUS-guided fine needle aspiration (FNA). During the time EUS was improved, electronic probes replaced mechanical probes adding ability ...

متن کامل

EUS elastography for diagnosis of solid pancreatic masses: a meta-analysis.

BACKGROUND The differential diagnosis of solid pancreatic masses has been a significant challenge up until now. EUS elastography is now used as a new technique to distinguish benign from malignant pancreatic masses. However, the sensitivity, specificity, and accuracy are still questionable. OBJECTIVE To evaluate the accuracy of EUS elastography for diagnosis of solid pancreatic masses. DESI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015