Determination of right ventricular mass in humans and dogs with ultrafast cardiac computed tomography.

نویسندگان

  • Z D Hajduczok
  • R M Weiss
  • W Stanford
  • M L Marcus
چکیده

There is currently no clinical approach to precisely measure right ventricular (RV) mass. We postulated that the radiological mode of ultrafast computed tomography (CT) of 3-mm-thick slices with 0.7-mm resolution would allow sufficient resolution to accurately estimate RV mass. Using this radiological mode, we serially imaged the entire right ventricle from apex to base, gated to end diastole, and applied Simpson's rule to calculate mass of the RV free wall. Thirteen mongrel dogs (weight, 6-30 kg) were studied. The free wall mass of the right ventricle was in the range of 12.0-47.5 g and averaged 35.4 +/- 3.7 g (mean +/- SEE). The correlation between RV mass estimated by ultrafast CT and actual RV mass was r equaling 0.85, SEE equaling 5.5 g, slope equaling 0.99, and gamma intercept equaling -1.8. Intraobserver and interobserver variability (r = 0.99 and r = 0.99, respectively) was excellent with a standard deviation (SD) equal to 1.5 and 1.8, respectively. The effect of variable RV preload (right atrial pressure, -5 to +20 mm Hg) on accuracy of RV mass measurements produced minimal error (SD = 3.6 g) in RV mass measurements. Seven normal young healthy men were also studied. The free wall mass of the right ventricle was in the range of 48.3-67.4 g and averaged 54.6 +/- 2.8 g (mean +/- SEE). The left ventricular to right ventricular (LV:RV) ratio averaged 3.2 +/- 0.2:1. These results are in agreement with human autopsy data in healthy males reporting mean RV mass equal to 46 g and an LV:RV ratio equal to 3.4:1. Because imaging every 3-mm slice from apex to base requires two contrast injections, we determined the accuracy of RV mass measurements if only every fourth 3-mm slice with interpolation was used. RV mass measurements using every slice or every fourth slice with interpolation were excellent (dogs, r = 0.99; humans, r = 0.97). It is concluded that high resolution CT imaging (3-mm tomograms) allows accurate measurements of RV mass. It is possible to add this stop-action mode of ultrafast CT, to previous CT studies, using every fourth tomographic slice for mass determinations and only one additional contrast injection of 40-60 ml. This should permit the study of progression and regression of RV mass in patients with various diseases.

منابع مشابه

Quantitative determination of aortic regurgitant volumes in dogs by ultrafast computed tomography.

Current imaging modalities can provide only a qualitative or semiquantitative measure of the severity of aortic regurgitation. Ultrafast computed tomography (CT) has the capability of rapid imaging (17 frames/sec) coupled with high spatial resolution (1.5 mm2). Eight millimeter thick images can be acquired to interrogate simultaneously the right and left ventricles. End-diastolic and end-systol...

متن کامل

Determination of left ventricular mass in dogs with rapid-acquisition cardiac computed tomographic scanning.

The development of left ventricular hypertrophy in patients with heart disease often has far-reaching clinical implications with respect to overall morbidity and mortality. Approaches used to assess left ventricular mass include electrocardiography, echocardiography, contrast ventriculography, single photon-emission tomography, and conventional computed tomography. However, all of these modalit...

متن کامل

Cardiac Metastasis of Breast Cancer: A Case Report

Breast cancer is one of the most common cancers in women. As we know, cardiac metastases occur rarely. In this study, a 40-year-old woman referred to the hospital due to severe pain in the right leg. She was diagnosed with deep vein thrombosis (DVT) and received treatment, but, after one month and a half she returned with severe pain, exacerbated shortness of breath, cramping pain, and chest pa...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Circulation

دوره 82 1  شماره 

صفحات  -