Beam-size effects in radiation damage in insulin and thaumatin crystals.
نویسندگان
چکیده
Cryocooled insulin and thaumatin crystals were irradiated in a series of alternating data collections and high-dose-rate exposures using either a vertically focused or vertically defocused beam. The main result is that the radiation damage is limited to the exposed region, which can be explained by the short range of the photoelectrons and the Auger electron cascade produced by light elements. Consequently, the unexposed angular range provides significantly improved data quality and electron density compared with previously exposed angular wedges of the crystal when a vertically focused beam is used, while no differences are observed between a fresh wedge and an exposed region for the vertically defocused beam. On the other hand, the focused beam provides higher I/sigma(I) ratios at high resolution than homogeneous sample illumination but also causes more rapid sample deterioration.
منابع مشابه
Identification of the point of diminishing returns in high-multiplicity data collection for sulfur SAD phasing
High-quality high-multiplicity X-ray diffraction data were collected on five different crystals of thaumatin using a homogeneous-profile X-ray beam at E = 8 keV to investigate the counteracting effects of increased multiplicity and increased radiation damage on the quality of anomalous diffraction data collected on macromolecular crystals. By comparing sulfur substructures obtained from subsets...
متن کاملImproving radiation-damage substructures for RIP.
Specific radiation damage can be used to solve macromolecular structures using the radiation-damage-induced phasing (RIP) method. The method has been investigated for six disulfide-containing test structures (elastase, insulin, lysozyme, ribonuclease A, trypsin and thaumatin) using data sets that were collected on a third-generation synchrotron undulator beamline with a highly attenuated beam. ...
متن کاملRadiation damage in room-temperature data acquisition with the PILATUS 6M pixel detector
The first study of room-temperature macromolecular crystallography data acquisition with a silicon pixel detector is presented, where the data are collected in continuous sample rotation mode, with millisecond read-out time and no read-out noise. Several successive datasets were collected sequentially from single test crystals of thaumatin and insulin. The dose rate ranged between ∼ 1320 Gy s(-...
متن کاملMatching X-ray source, optics and detectors to protein crystallography requirements.
A review of the requirements for collecting X-ray diffraction data from protein crystals is given, with an emphasis on the properties of the crystal and its diffraction pattern. The size, unit-cell dimensions and perfection of the crystals can all be related to the required size and divergence of the incident X-ray beam, together with the size and spatial resolution of the detector. The X-ray b...
متن کاملConformational variation of proteins at room temperature is not dominated by radiation damage
Protein crystallography data collection at synchrotrons is routinely carried out at cryogenic temperatures to mitigate radiation damage. Although damage still takes place at 100 K and below, the immobilization of free radicals increases the lifetime of the crystals by approximately 100-fold. Recent studies have shown that flash-cooling decreases the heterogeneity of the conformational ensemble ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 12 Pt 3 شماره
صفحات -
تاریخ انتشار 2005