Comparative study between pure tone audiometry and auditory steady-state responses in normal hearing subjects.

نویسندگان

  • Roberto Miquelino de Oliveira Beck
  • Bernardo Faria Ramos
  • Signe Schuster Grasel
  • Henrique Faria Ramos
  • Maria Flávia Bonadia B de Moraes
  • Edigar Rezende de Almeida
  • Ricardo Ferreira Bento
چکیده

INTRODUCTION Auditory steady-state responses (ASSR) are an important tool to detect objectively frequency-specific hearing thresholds. Pure-tone audiometry is the gold-standard for hearing evaluation, although sometimes it may be inconclusive, especially in children and uncooperative adults. AIM Compare pure tone thresholds (PT) with ASSR thresholds in normal hearing subjects. MATERIALS AND METHODS In this prospective cross-sectional study we included 26 adults (n = 52 ears) of both genders, without any hearing complaints or otologic diseases and normal puretone thresholds. All subjects had clinical history, otomicroscopy, audiometry and immitance measurements. This evaluation was followed by the ASSR test. The mean pure-tone and ASSR thresholds for each frequency were calculated. RESULTS The mean difference between PTand ASSR thresholdswas 7,12 for 500 Hz, 7,6 for 1000 Hz, 8,27 for 2000 Hz and 9,71 dB for 4000 Hz. There were no difference between PT and ASSR means at either frequency. CONCLUSION ASSR thresholds were comparable to pure-tone thresholds in normal hearing adults. Nevertheless it should not be used as the only method of hearing evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخ‌های برانگیخته قشر شنوایی

Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...

متن کامل

Comparison between auditory steady-state responses and pure-tone audiometry.

BACKGROUND/AIM A more recent method, the auditory steady-state response (ASSR), has become more and more important test method due to difference that was found in previous investigations between hearing thresholds determined by the ASSR and the pure-tone audiometry (PTA). The aim of this study was to evaluate the reliability of the ASSR in determining the frequency specific hearing thresholds b...

متن کامل

Comparing pure-tone audiometry and auditory steady state response for the measurement of hearing loss.

OBJECTIVE To compare pure-tone audiometry and auditory steady state response (ASSR) to measure hearing loss based on the severity of hearing loss in frequencies. STUDY DESIGN AND SETTING A total of 105 subjects (168 ears, 64 male and 41 female) were enrolled in this study. We determined hearing level by measurement of pure-tone audiometry and ASSR on the same day for each subject. RESULTS P...

متن کامل

Hearing threshold prediction with Auditory Steady State Responses and estimation of correction functions to compensate for differences with behavioral data, in adult subjects

BACKGROUND The objective of the study was the evaluation and comparison of hearing threshold values extrapolated from Auditory Steady State Responses, using 2 commercial systems and the estimation of correction factors applicable to the ASSR data. MATERIAL/METHODS One hundred ten subjects participated to the study. All subjects were initially examined with otoscopy, pure-tone audiometry and a...

متن کامل

[Multiple auditory steady-state responses to bone conduction stimuli].

OBJECTIVE To assess the accuracy of threshold using the multiple auditory steady state responses (MASSR) to bone conduction stimuli in a group of patients with conductive hearing loss. METHOD Thirty patients with conductive hearing loss were assessed by MASSR and by pure-tone audiometry, and compared the results of these two methods. RESULT The thresholds of MASSR and those of PTA were sign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of otorhinolaryngology

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 2014