Load transfer by an implant in a sinus-grafted maxillary model.

نویسندگان

  • Mete I Fanuscu
  • Keisuke Iida
  • Angelo A Caputo
  • Russell D Nishimura
چکیده

PURPOSE This in vitro study determined the stress distribution around an implant placed in a posterior edentulous maxillary model with simulated sinus grafts that had different degrees of stiffness. MATERIALS AND METHODS The composite photoelastic model with a standard threaded implant consisted of simulated crestal cortical, cancellous, sinus cortical, and grafted bone. The graft maturation process and inherent graft quality were represented in the model by varying the stiffness of the graft. Prior to placement of the simulated graft, axial and inclined loads were applied to the implant The stresses that developed in the supporting structures were analyzed photoelastically. The graft was then placed and the testing procedure was repeated over 4 consecutive days, during which time the simulated graft stiffened. RESULTS The stress analysis indicated that before placement of the simulated graft, loading on the implant transferred the highest stresses to cortical bone. The presence of the simulated graft transferred stress from the native bone simulants to the simulated grafted bone. DISCUSSION As the stiffness of the graft increased, a more equitable stress distribution was observed in the multilayer bone surrounding the implant. CONCLUSION Loading of an implant in a less stiff grafted sinus could lead to overloading of the native bone as well as the maturing grafted bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran

BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...

متن کامل

Remodeling of Autogenous Bone Grafts after Osteotome Sinus Floor Elevation Assessed by Limited Cone Beam Computed Tomography

This study assessed the radiographic appearance of bone graft domes longitudinally after osteotome sinus floor elevation using cone beam computed tomography (CBCT). This study presents the radiological findings of a 6-month follow-up CBCT study in maxillary osteotome sinus floor elevation. We examined 52 patients with a crestal bone height of less than 8 mm in the posterior maxilla who required...

متن کامل

Using Absorbable Gelatin Sponge to Facilitate Sinus Membrane Elevation during Open Sinus Lift: Technical Notes and Case Series

Ridge atrophy accompanied by the pneumatization of maxillary sinus in the maxillary posterior region may lead to inadequate bone height, thereby precluding implant placement. Therefore, it may be mandatory to perform a sinus membrane elevation procedure and augmentation in the bone. The present study aimed to introduce a novel modification method for sinus floor elevation using a gelatin sponge...

متن کامل

Assessment of the autogenous bone graft for sinus elevation

OBJECTIVES The posterior maxillary region often provides a limited bone volume for dental implants. Maxillary sinus elevation via inserting a bone graft through a window opened in the lateral sinus wall has become the most common surgical procedure for increasing the alveolar bone height in place of dental implants in the posterior maxillary region. The purpose of this article is to assess the ...

متن کامل

Two-stage maxillary sinus reconstruction with endosseous implants: a prospective study.

The aim of this prospective study was to evaluate the results of 2-stage maxillary sinus reconstruction using titanium implants placed into iliac corticocancellous bone blocks previously grafted to the floor of sinuses. Fifty consecutive patients received 314 Brånemark implants of varying lengths; 202 implants were placed in the grafted bone and 112 were placed in the adjacent anterior maxillar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2003