Assessment of radiopharmaceutical retention for vascular access ports using positron emission tomography imaging

نویسندگان

  • Michael S. Gossman
  • Huaiyu Zheng
  • John G. Evans
  • Junling Li
  • Chin K. Ng
چکیده

PURPOSE The purpose of this study was to resolve the issue of whether various generations of CR Bard peripheral vascular access ports and catheters are prone to retain PET radiopharmaceuticals. The study evaluates the residual radioactivity remaining following injection for two PET radiopharmaceuticals currently used extensively in the clinic, FDG and Na18 F. METHODS FDG was purchased from a local cyclotron facility and Na18 F was prepared in-house. Three generations of currently marketed vascular access ports were tested. A total of five (n = 5) of each model was tested. Radiopharmaceutical of 2-3 mCi of each was injected into each port and flushed with 10, 30, 60, and 120 ml of saline. MicroPET scans were performed after each flush to detect the residual radioactivity on each port. A dose calibrator was used to detect the retention of radioactivity after each flush. RESULTS Radioactivity retention for all vascular port models measured by microPET imaging was similar for both FDG and Na18 F, with less than 1% residual activity following a 10 ml saline flush. Based on the microPET images, all the subsequent flushes of 30, 60, and 120 ml were also considered. Dose calibrator activity measurements validated microPET measurements as negligible for all the ports, even with the first 10 ml flush. CONCLUSIONS MicroPET imaging was more sensitive than the dose calibrator in determining the radioactivity retention of the vascular access ports from CR Bard. These ports may be used for the injection of FDG and Na18 F to track glucose metabolism and bone uptake with PET imaging. It is recommended to apply at least a 10 ml flush after radiopharmaceutical administration, to reduce residual activity to baseline levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017