Ion-selective electrode and anion gap range: What should the anion gap be?

نویسندگان

  • Seyed-Ali Sadjadi
  • Rendell Manalo
  • Navin Jaipaul
  • James McMillan
چکیده

BACKGROUND Using flame photometry technique in the 1970s, the normal value of anion gap (AG) was determined to be 12 ± 4 meq/L. However, with introduction of the autoanalyzers using an ion-selective electrode (ISE), the anion gap value has fallen to lower levels. METHODS A retrospective study of US veterans from a single medical center was performed to determine the value of the anion gap in subjects with normal renal function and normal serum albumin and in patients with lactic acidosis and end-stage renal disease on dialysis. RESULTS In 409 patients with an estimated glomerular filtration rate ≥60 mL/min/1.73 m(2) body surface area and serum albumin ≥4 g/dL, the mean AG was 7.2 ± 2 (range 3-11) meq/L. In 299 patients with lactic acidosis (lactate level ≥4 meq/L) and 68 patients with endstage renal disease on dialysis, the mean AG was 12.5 meq/L and 12.4 meq/L, respectively. A value <2 meq/L should be considered a low anion gap and a possible clue to drug intoxication and paraproteinemic disorders. CONCLUSION With the advent of ISE for measurement of analytes, the value of the anion gap has fallen. Physicians need to be aware of the normal AG value in their respective institutions, and laboratories need to have an established value for AG based on the type of instrument they are using.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

Clinical Usefulness of the Serum Anion Gap

The anion gap in the serum is useful in the interpretation of acid-base disorders and in the diagnosis of other conditions. In the early 1980s, ion-selective electrodes for specific ionic species were introduced for the measurement of serum electrolytes. This new method has caused a shift of the anion gap from 12±4 mEq/L down 6±3 mEq/L. It is worthy for clinicians to understand the range of nor...

متن کامل

Diabetic Ketoalkalosis after Steroid Pulse Therapy in a Patient with Pancreas Transplant Rejection

Diabetic ketoacidosis (DKA) is characterized by excessive production of organic acids leading to a low blood pH. Rarely, because of other complicating factors blood pH may be in the alkalemic range and the term diabetic ketoalkalosis has been coined to describe this condition. So far, less than 30 such cases have been reported in the literature. We report a 34-year-old woman who received methyl...

متن کامل

PVC-Based Cerium Phosphate Membrane Exhibiting Selectivity for Molybdate Anions

A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. Therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. The response of molybdate selective electrode based on this membrane was perfectly linear in the concentr...

متن کامل

An Improvement to the Properties of GAP Binder with Energetic Ionic Liquids

Glycidyl azide polymer (GAP) is used as a binder in the propellants. Energetic ionic liquids are used as a plasticizer to correct the properties of polymer. In this study, first ionic liquid was bonded to the GAP by certain amount and then the energetic anions of nitrate (NO3) and azide (N3) were used to exchange anion. FTIR analyses confirm accurately anions exchange. DSC, viscometer and heat ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013