Objective autorefraction in posterior chamber pseudophakia.
نویسندگان
چکیده
Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 110 eyes (110 patients) six to eight weeks after they had undergone extracapsular cataract extraction with posterior chamber intraocular lens implantation and achieved a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 100 (91%) of these eyes. The agreement between autorefraction and clinical refraction data was 98% for spherical equivalence less than 0.51 dioptres (D), 95% for sphere power less than 0.51D, 94% for cylinder power less than 0.51D, and 85% for cylinder axis less than 11 degrees. Autorefraction can provide acceptably accurate postoperative refraction values in pseudophakic eyes.
منابع مشابه
Clinical evaluation of automated refraction in anterior chamber pseudophakia.
Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 85 eyes of 85 patients with an anterior chamber intraocular lens implant and a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 80 (94%) of these eyes. The agreement between autorefraction and clinical refraction data was 89% for spherical equivalence less than 0.51 dioptres (D),...
متن کاملSteeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study
PURPOSE To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. METHODS A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed incl...
متن کاملSecondary open-angle pigmentary glaucoma resulting from pseudophakia. Case report.
PURPOSE To report the case of a 60-year-old man with a pseudophakia-related secondary open-angle pigmentary glaucoma without individual hereditary steroid susceptibility. METHODS The clinical and functional evaluations of the patient were thoroughly and specifically carried out. RESULTS The unilateral pseudophakic open-angle pigmentary glaucoma occurred in the context of rubbing of the hapt...
متن کاملColour perception in pseudophakia.
Minor differences in colour perception between pseudophakic, phakic, and spectacle aphakic eyes were identified by the Pickford-Nicholson anomaloscope and the Farnsworth-Munsell 100-hue test. The results suggest that pseudophakic eyes are more sensitive to red and less sensitive to blue than aphakic eyes corrected with spectacles. Spectrophotometer measurements reveal that the Rayner-Pearce pos...
متن کاملNumerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues
Introduction: The present study aimed to present a numerical analysis of the penetration depth, specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 74 12 شماره
صفحات -
تاریخ انتشار 1990