A new device for measurement of fibrin clot lysis: application to the Euglobulin Clot Lysis Time
نویسندگان
چکیده
BACKGROUND Determination of clot lysis times on whole blood, diluted whole blood, plasma or plasma fraction has been used for many years to assess the overall activity of the fibrinolytic system. We designed a completely computerised semi-automatic 8-channel device for measurement and determination of fibrin clot lysis. The lysis time is evaluated by a mathematical analysis of the lysis curve and the results are expressed in minute (range: 5 to 9999). We have used this new device for Euglobulin Clot Lysis Time (ECLT) determination, which is the most common test used in laboratories to estimate plasma fibrinolytic capacity. RESULTS The correlation between ECLT and manual method is very tight : R = 0,99; p < 10(-6). The efficiency scores of the method are <4% in intra-assay and <7% in inter-assay. It allows to achieve the tests on hyperlipaemic samples. This new device has been easily integrated in laboratory routine and allows to achieve several ECLT every day without disturbance of laboratory workflow. CONCLUSIONS The routine use of this new device could be useful in various situations such as assessment in atherosclerosis and arteriosclerosis associated diseases, coagulation survey of liver transplantations, cardiovascular surgery or pharmacological research.It has already provided highly promising results in preliminary studies on the relation between fibrinolysis and cardiovascular risk factors.
منابع مشابه
Automatic determination of euglobulin lysis time.
Despite the criticisms of substrate variability, the euglobulin lysis time remains a most useful assay of plasma plasminogen activator. It is simple to execute and correlates well with the radioactive clot assay (Sawyer, Fletcher, Alkjaersig, and Sherry, 1960), dilute blood clot lysis time (Fearnley, Balmforth, and Feamley, 1957), and fibrin plate method (Kekwick and Mackay, 1954). It continues...
متن کاملThe euglobulin lysis time test: an ineffectual monitor of the therapeutic inhibition of fibrinolysis.
In two clinical situations associated with hyperfibrinolysis the administration of antifibrinolytic drugs resulted in clinical haemostasis. The dilute clot lysis time and fibrin plate activity test but not the euglobulin lysis time reflected this control of excessive fibrinolysis by the antifibrinolytic drugs. The inhibition by epsilon-amino-caproic acid (EACA) of hyperfibrinolysis induced in v...
متن کاملOf Antibiotics Studies on Wb - 3559 a , B , C and D , New Potent Fibrinolytic Agents
WB-3559 A, B, C and D were produced by a bacterium which was classified as a member of the genus Flavobacterium. These compounds were purified by solvent extraction followed by chromatography on silica gel and then isolated by HPLC. The chemical structures were determined on the basis of chemical and spectroscopic evidence as in the succeeding papers. WB-3559 A, B, C and D stimulated rabbit pla...
متن کاملFeasibility of recording clot lysis with the thermometric clot detector.
Currently, the study of fibrinolysis is beset by problems of methodology (1 ). Disadvantages of many of the present methods for measurement of clot lysisincluding lysis time for the dilute blood clot, thromboelastography, euglobulin clot lysis, fibrin plate method, and caseinolytic assay (1 )-are imprecision of results and time required to perform the test (2). The electromechanical lysis timer...
متن کاملSemi-automatic method for routine evaluation of fibrinolytic components.
A semi-automatic method for the routine evaluation of fibrinolytic activity is described. The principle is based upon graphic recording by a multichannel voltmeter of tension drops over a potentiometer, caused by variations in the influence of light upon a light-dependent resistance, resulting from modifications in the composition of the fibrin fibres by lysis. The method is applied to the asse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Biotechnology
دوره 2 شماره
صفحات -
تاریخ انتشار 2002