Degradation of charge sharing after neutron irradiation in strip silicon detectors with different geometries

نویسندگان

  • G. Casse
  • P. Dervan
  • D. Forshaw
  • A. Greenall
  • T. Huse
  • I. Tsurin
  • M. Wormald
چکیده

The aim of the CERN/RD50 collaboration is the improvement of the radiation tolerance of semiconductor detectors for future experiments at high-luminosity colliders. In the RD50 framework, evidence of enhanced signal charge in severely irradiated silicon detectors (diodes, segmented planar and 3D devices) was found. The underlying mechanism was labelled charge multiplication. This has been one of the most exciting results from the research activity of RD50 because it could allow for a greatly extended radiation tolerance, if the mechanism is to be found controllable and tuneable. The charge multiplication mechanism is governed by impact ionisation from electrons drifting in high electric field. The electric field profile is influenced by the geometry of the implanted electrodes. In order to investigate the influence of the diode implantation geometry on charge multiplication, the RD50 collaboration has commissioned the production of miniature microstrip silicon sensors with various choices of strip pitch and strip width over pitch (w/p) ratios. Moreover, some of the sensors were produced interleaving readout strips with dummy intermediate ones in order to modify the electric field profile. These geometrical solutions can influence both charge multiplication and charge sharing between adjacent strips. The initial results of this study are here presented. & 2013 CERN. Published by Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics and SPICE simulation of a single - sided , n + on n Si strip detector before and after neutron irradiation

Capacitance, resistance and current measurements were carried out on single-sided, n + on n silicon strip detectors. We studied the type inversion after irradiating the detectors with neutron fluences up to 8:3 10 13 neutron=cm 2. To understand the macroscopic irradiation effects, a SPICE model of the detector was developed. By modelling the setup of the capacitance measurements, our model was ...

متن کامل

Beam test results on n on n type silicon microstrip detectors before and after neutron irradiation

We present beam test results on AC-coupled, single-sided, n-on-n type silicon microstrip detectors. We have tested the detectors before and after irradiation at a fluence of 8.3× 10 n/cm, at different temperatures and bias voltages. The signal-to-noise ratio, spatial resolution, charge collection and overall efficiency have been measured.

متن کامل

Charge collection measurements with p-type Magnetic Czochralski Silicon single pad detectors

The charge collected from beta source particles in single pad detectors produced on p-type Magnetic Czochralski (MCz) silicon wafers has been measured before and after irradiation with 26 MeV protons. After a 1MeV neutron equivalent fluence of 1x10 cm the collected charge is reduced to 77% at bias voltages below 900 V. This result is compared with previous results from charge collection measure...

متن کامل

Design and Tests of the Silicon Sensors for the ZEUS Micro Vertex Detector

To fully exploit the HERA-II upgrade, the ZEUS experiment has installed a Micro Vertex Detector (MVD) using n-type, single-sided, silicon μ-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 μm, with five intermediate strips (20 μm strip pitch). The designs of the silicon sensors and of the test structures used to verify the technological parameters, are pres...

متن کامل

Specification of Irradiation Conditions in the DONA 5 Rotational Channel of the LVR-15 Reactor

This article summarizes ways to verify neutron fluence for neutron transmutation doping of silicon with phosphorus on the LVR-15 reactor. Neutron fluence is determined using activation detectors placed along the crystal in a strip or encapsulated in a rod holder. Holders are placed at the centre of a water-filled capsule or in an aluminum or silicon ingot that simulates a real single crystal. I...